TROUBLESHOOTING AND REPAIR
RETEST AFTER REPAIR
F-94 F-94
V350-PRO
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
Required Action
Expected Results
Rt. displayLft.display
Test
Steps
23
24
25
26
27
28
29
30
31
32
Verify that the Advanced Process Panel upper right dis-
play contains the following pattern and that the bright-
ness of the characters is uniform:
“0123456789ABCDEF”
Press and release the Advanced Process Panel
Memory button to advance to the next step.
Verify that the Advanced Process Panel lower right dis-
play contains the following pattern and that the bright-
ness of the characters is uniform:
“0123456789ABCDEF”
Press and release the Advanced Process Panel
Memory button to advance to the next step.
The weld terminals “ON” and “REMOTE” LEDs should
both be off. Press the weld terminals push button to
select weld terminals (studs) “ON” and verify that the
weld terminals “ON” LED turns on.
Press the weld terminals push button again to select
weld terminals “REMOTE” and verify that the weld ter-
minals “ON” LED turns off and that the weld terminals
“REMOTE” LED turns on.
Press the weld terminals push button again and verify
that both of the weld terminals LEDs are off.
The “LOCAL” and “REMOTE” workpoint source LEDs
should both be off. Press the workpoint source push
button to select “LOCAL” and verify that the workpoint
source “LOCAL” LED turns on and that the “REMOTE”
workpoint source LED remains off.
Press the workpoint source pushbutton again to select
workpoint source “REMOTE” and verify that the work-
point source “LOCAL” LED turns off and the workpoint
source “REMOTE” workpoint source LED turns on.
Press the workpoint source pushbutton again and verify
that both workpoint source LEDs are off.
This will only appear if a potentiometer is already con-
nected to the 6-pin amphenol connector on the front of
the machine. If this message appears, disconnect the
potentiometer from the 6-pin amphenol connector.
Connect a remote output control potentiometer to the 6-
pin amphenol connector on the front of the machine.
dISP
dISP
SudS
SudS
SudS
LorE
LorE
LorE
dcon
con
3
4
on
rE
cLr
LocL
rE
cLr
6-PIn roCP
6-PIn roCP