Tips
Symptom Cause / Solution Page
Power turns o and the power
indicator flashes red approx. every 0.5
seconds.
•Due to the temperature rise within this unit, the protection circuit is working. Turn o the
power and wait about an hour until this unit suciently cools down. Then, turn on the power
again.
•Please re-install this unit in a place having good ventilation.
39
Power turns o and the power
indicator flashes red approx. every
0.25 seconds.
•Check the speaker connection. The protection circuit may have been activated because
speaker cable core wires came in contact with each other or a core wire was disconnected
from the connector and came in contact with the rear panel of this unit. After unplugging the
power cord, take corrective action such as firmly re-twisting the core wire or taking care of the
connector, and then reconnect the wire.
•Turn down the volume and turn on the power again.
16, 39
25, 26
When the power is turned on, the
power indicator flashes red approx.
every 0.25 seconds.
•This unit’s amplifier circuit has failed. Turn o the power and please contact the Marantz
service adviser.