If the exhaust is ducted into an
inactive flue, the air must be expelled
parallel to the flow direction of the
flue.
Never connect an exhaust hood to
an active chimney, dryer vent, flue,
or room venting ductwork. Seek
professional advice before
connecting an exhaust hood vent to
an existing, inactive chimney or vent
flue.
Important!
If the ductwork runs through cool
rooms, ceilings, etc. large temperature
variations may occur in places. This
can lead to moisture and condensation.
It will be necessary to insulate the
exhaust ducting.
Condensate trap
(optional accessory)
Besides appropriate insulation of the
exhaust ducting, we recommend
installing a condensate trap to collect
and evaporate any condensation which
may develop. This is available for ducts
C 5" (125 mm) or C 6" (150 mm).
When installing a condensate trap,
ensure that it is positioned vertically
and if possible directly above the
exhaust outlet of the ventilation hood.
The arrow on the casing indicates the
exhaust flow direction.
Air extraction