ENG
Connection & Control
SWITCH SETTING TABLE
Use a combination of pin 1,2,3,4 of the Protocol setting switch to select a protocol.
TERMINATION
1
ON
2
PROTOCOL
1
ON
23456781
ON
234
Protocol Setting Switch (0 :r, 1 :q)
Protocol HALF/
Pin 1 Pin 2 Pin 3 Pin 4
0 0 0 0 SAMSUNG HALF
1 0 0 0 SAMSUNG FULL
1 1 0 0 PANASONIC HALF
0 0 1 0 PANASONIC FULL
1 1 1 0 PHILIPS HALF
1 0 0 1 KALATEL HALF
0 1 0 1 ERNA HALF
1 1 0 1 DIAMOND HALF
0 0 1 1 VCL TP HALF
By default, it is configured to support SAMSUNG and PANASONIC.
For other protocols, you can find assistance from our website at:
http://www.samsungsecurity.com
NOTE
Use pin 7 and 8 of the Protocol setting switch to set the coaxial output.
PROTOCOL
1
ON
23456787
PIN 7 Output Selection
ON COAXIAL out
OFF RS-485 out
PROTOCOL
1
ON
23456788
PIN 8 RS-232 input
ON RS-232 input
OFF RS-232 No use
RS-232 and RS-485 communications cannot be used for simultaneous input.
NOTE
HALF : half-duplex
FULL : full-duplex