![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/c/e5/ce5ce9a1-4d18-49fd-81e0-478efa76a6aa/ce5ce9a1-4d18-49fd-81e0-478efa76a6aa-bg45.png)
Series 24-HP Instruction Manual Appendix A Specifications
IM-24-HP A-3
Nominal Pipe Size (in)
Pressure 0.5 0.75 1 1.5 2 3 4 6 8
1170 2760 5988 14711 24582 54987 95710 217001 380148
300 psig
400 psig
500 psig
Typical Saturated Steam Minimum and Maximum Flow Rates (lb/hr)
5 psig
100 psig
200 psig
Nominal Pipe Size (mm)
Pressure 0.5 0.75 1 1.5 2 3 4 6 8
463 1092 2370 5822 9729 21763 37880 85884 150451
15 barg
20 barg
30 barg
Typical Saturated Steam Minimum and Maximum Flow Rates (kg/hr)
0 barg
5 barg
10 barg
Linear Range Smart electronics corrects for lower flow down to a Reynolds number of 5,000. The Reynolds
number is calculated using the fluid’s actual temperature and pres-
sure monitored by the meter. Rangeability depends on the fluid,
process connections and pipe size. Consult factory for your applica-
tion. Velocity rangeability under ideal conditions is as follows:
Liquids 30:1 1 foot per second velocity minimum
30 feet per second velocity maximum
Gases 30:1 10 feet per second velocity minimum
300 feet per second velocity maximum
Process Fluid Pressure
240 Pressure Ratings
Process
Connection
Material Rating
Flanged 316L SS, A105 Carbon Steel, C276 Hastelloy 150, 300, 600 lb, PN16,
PN40, PN64
Wafer 316L SS, A105 Carbon Steel, C276 Hastelloy 600 lb, PN64