![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/62/262cc296-cf92-4421-95f9-f9a629e1556e/262cc296-cf92-4421-95f9-f9a629e1556e-bgb.png)
9
FWD-S42H1
6. Priority Signal Select Function
(a) Mode Control
Syntax Header Category Function Data1 Data2 Check Sum
Enquiry 0x83 0x00 Code Table (2-a) [a] Code Table (2-d) 0xFF 0xXX
Answer Header Answer Return to Data Size Return Data1 Data2 Check Sum
Enquiry 0x70 0x00 0x02 Code Table (2-a) [b] 0xFF 0xXX Completed
Code Table (2-a)
[a]Function [b]Range/Switch Code Command
Control Enquiry Standby Power On
0x77 Priority Signal Select 0x00 Input1 Auto No Yes Disable Enable
0x01 Input1 RGB
0x02 Input1 YPbPr
Code Table (2-d)
Input Select
0x00 HD15
0x01 Option
(b) Time Control
Data Set (Month, Date)
Syntax Header Category Function Data1 Data2 Data3 Check Sum
Control 0x8C 0x00 0x7C 0x03 Month: 0x01-0x0C Date: 0x01-0x1F 0xXX
Syntax Header Category Function Data1 Data2 Check Sum
Enquiry 0x83 0x00 0x7C 0xFF 0xFF 0xFD
Answer Header Answer Check Sum
Control 0x70 0x00 0x70 Completed
0x70 0x01 0x71 Limit Over
0x70 0x02 0x72 Limit Under
0x70 0x03 0x73 Command Canceled
Answer Header Answer Return to Data Size Return Data1 Return Data2 Check Sum
Enquiry 0x70 0x00 0x03 Month: 0x00-0x0C Date: 0x01-0x1F 0xXX Completed