![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/d/c0/dc0436ba-c408-4546-b6b4-203a07279cfc/dc0436ba-c408-4546-b6b4-203a07279cfc-bg11.png)
83-507-5002 Rev. B
9
CHAPTER 2 SPECIFICATIONS
1.Rated output voltage (*1)
2.Rated output current 750W (*2)
3.Rated output power 750W
1.Rated output voltage (*1)
2.Rated Output Current 1500W (*2)
3.Rated output power 1500W
2.2 INPUT CHARACTERISTICS
1. Input voltage/freq. (*3)
2. Input current (at 100/200Vac)
4. 750W models Efficiency (*4)
5. 1500W models Efficiency (*4)
6. Inrush current at 100/200V
2.3 CONSTANT VOLTAGE MODE
1. Max.Line regulation (*5)
2. Max.Load regulation (*6)
3. Ripple and noise (p-p,20MHz) (*10)
4. Ripple r.m.s., 5Hz~1MHz (*10)
5. Temperature coefficient
100PPM/°C of rated output voltage, following 30 min utes warm up
7. Rem. Sense compensation/wire
8. Up-prog. Response time 0~Vomax (*9)
9. Down-prog. Response time: Full load
10. Transient response time
2.4 CONSTANT CURRENT MODE
1. Max.line regulation (*5)
2. Max.load regulation (*7)
3. Ripple r.m.s. 5Hz~1MHz.750W (*8)
4. Temperature coefficient
2.5 ANALOG PROGRAMMING AND MONITORING
1.Vout voltage programming
2. Iout voltage programming
3. Vout resistor progrmming
4. Iout resistor programming
6. Output current monitor
7. Output voltage monitor
8. Power supply OK signal
13. Local/Remote analog control
14. Local/remote analog indicator
85~265Vac continuous, 47-63Hz, single phase.
10.5/5 for 750W model, 21/11 for 1500W models.
0.99@100/200Vac, rated output power.
Less than 25A for 750W models, 50A for 1500W models.
0.01% of rated output voltage +2mV
0.01% of rated output voltage +2mV
0.05% of rated Vout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp.
Time for the output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated
Output set-point: 10~100%.
Less than 1mS for models up to and including 100V; 2mS for models above 100V.
More than 20mS, 100Vac, rated output power.
0.01% of rated output voltage +2mA
0.02% of rated output current +5mA
100PPM/°C from rated output current, following 30 m inutes warm-up.
0.05% of rated lout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp.
0~100%, 0~5V or 0~10V, user select. Accuracy and linearity; +/-0.5% of rated Vout.
0~100%, 0~5V or 0~10V, user select. Accuracy and linearity; +/-1% of rated Iout.
0~100%, 0~5/10Kohm full scale, user select. Accuracy and linearity: +/-1% of rated Vout.
0~100%, 0~5/10Kohm full scale, user select. Accuracy and linearity: +/-1.5% of rated Iout.
By electrical Voltage: 0~0.6V/2~15V or dry contact, user selectable logic.
0~5V or 0~10V, user selectable. Accuracy: 1%
0~5V or 0~10V, user selectable. Accuracy: 1%
4~5V-OK, 0V-Fail, 500ohm series resistance.
Possible, up to 4 units in master/slave mode with single wire current balance connection.
Possible (with external diodes), up to 2 units.
CV: TTL high (4~5V), source current: 10mA, CC: TTL low (0-0.6V). Sink current: 10mA .
Dry contact. Open: off, Short: on. Max. voltage at Enable/Disable in: 6V.
By electrical signal or Open/Short: 0~0.6V or short: Remote, 4~5V or open: Local.
Open collector. Local: Open, Remote: On. Maximum voltage: 30V, maximum sink current: 5mA.