TRIGger[:A] Subsystem
TVS600 & TVS600A Command Reference
2–233
Changing trigger coupling from DC to AC may cause TRIGger:LEVel to change
if level is out of range for AC coupling.
When TRIGger:A and TRIGger:B share the same SOURce, changing COUPling
for one will change COUPling for the other.
Command: TRIG:COUP:ACNR
TRIGger:COUPling
TRIGger:FILTer[:LPASs]
TRIGger:FILTer:HPASs
TRIGger:FILTer:NREJect
TRIGger:DEFine? (Query Only)
This query returns the predefined SEQuence1 alias, A. ARM:DEFine? and
TRIGger:DEFine? return the same information.
TRIGger[:SEQuence[1]]:DEFine?
<sequence_alias> Query response
Not applicable <string>
“A”
“A”
None
None
Query: TRIG:DEF?
Response: "A"
ARM:DEFine?
TRIGger:SEQuence2:DEFine?
Examples
Related Commands
Syntax
Parameters
Reset Value
Errors and Events
Dependencies
Examples
Related Commands