![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/b/23/b23af1eb-68fe-45c3-adba-a5e39b7d6ad9/b23af1eb-68fe-45c3-adba-a5e39b7d6ad9-bg31.png)
11. PROGRAMMING PROCEDURES
11.15 LON SYSTEM
11-24
11.15 LON SYSTEM
Menu Page: 2
Item No.: 4
The SL-9000 scales which consists of a master, satellites, and a backup master are connected each
other by the LON cable to transmit data such as PLU, ING., NUTRI, etc.
ID# 1 is reserved for the master terminal.
ID# 2 is reserved for the backup master terminal or satellite terminal.
ID# 3 to 32 are for satellite terminals.
Setting numbers other than the above results in an error.
4
PROG.
ESC.
Page 2
<MENU>
Yes
IN-LINE ↔ OFF-LINE
ENTER
m
Set the number of
ENTER
DLL? n
ID#: 1
p
m
No
CHANGE
PLU
NOTES: 1. Before starting the above procedure, press the key and enter IN-LINE
mode.
2. When installing the backup master terminal, set the master scale’s initial status
of #9-1 to 1.
3. Set ID # to all scales connected by LON cable.
4. When the display power is turned on, a satellite terminal is ready to receive data
from the master terminal.
5. After setting the ID #, turn the power switch OFF and ON again.