Table 2-5: Power Consumption
Power
Typical
units
Standby
1
mW
Operating
450
mW
2.4.4 Capacitance
Table 2-6: Bus Line Capacitance
Parameter Symbol Min Max Unit
Bus line capacitance C
L
- 20 pF
2.5 Environmental Conditions
2.5.1 Temperature and Altitude
Table 2-7: Temperature and Altitude Related Specifications
Conditions
Operating
Shipping
Storage
Commercial
Temperature
0 to 70°C
(32 to 158° F)
-40 to 85°C
(-40 to 185° F)
-40 to 85°C
(-40 to 185° F)
Industrial
Temperature
1
-40 to 85°C
(-40 to 185° F)
-40 to 85°C
(-40 to 185° F)
-40 to 85°C
(-40 to 185° F)
Humidity (non-
condensing)
5% to 95% 5% to 95% 5% to 95%
Max Temperature
Gradient
20°C/Hour
(36°F/Hour)
n/a n/a
Altitude
-304.8 to 24,384 m
(-1,000 to 80,000 ft)
-304.8 to 24,384 m
(-1,000 to 80,000 ft)
-304.8 to 24,384 m
(-1,000 to 80,000 ft)
Storage Time
Duration
n/a n/a 1 year
Notes:
1. SLC flash based products are available in the following temperature ranges:
a) Commercial temperature range of 0 to 70°C (32 to 158° F)
b) Industrial temperature range -40 to 85°C (-40 to 185° F)
2.6 Reliability
Table 2-8: Reliability Specifications
Parameter
Value
Mean Time Between Failures (MTBF)
1
2,500,000 hours
Power On/Off Cycles
2
50,000 cycles