A SERVICE OF

logo

Manual
6/12/2014
PSFEM1XXXGPXXX
Viking Technology
Revision B4
Page 38 of 48
www.vikingtechnology.com
ID
Attribute Name
Description
Rational
[6-4] : None (0x00)
171
Program Fail
Count
Counts the number of flash program
failures.
Usage:
[6-4] : None (0x00)
[3-0] : Program Error Count
This Attribute returns the total
number of Flash program
operation failures since the
drive was deployed.
This Attribute is identical to
Attribute 181.
172
Erase Fail Count
Counts the number of flash erase
failures.
Usage:
[6-4] : None (0x00)
[3-0] : Erase Error Count
This Attribute returns the total
number of Flash erase operation
failures since the drive
was deployed.
This Attribute is identical to
Attribute 182.
174
Unexpected
Power Loss
Counts the number of unexpected
power loss events, as determined by
the number of times PFAIL has been
asserted (or other criteria?).
Usage:
[6-4] : None (0x00)
[3-0] : Unexpected Power Loss Event
Count
This Attribute returns the total
number of unexpected power
loss events over the life of
the drive.