P.O. Box 696
■
Louisville, KY 40201
■
Toll-free: 1-800-814-2028
■
Local: 502-778-2791
■
Quote & Order Fax: 1-800-444-0602
a division of ITW Food Equipment Group LLC
STEAM
F-32050 (04/10)
VGL SERIES
GAS STATIONARY
2
⁄
3
JACKETED KETTLES
NOTE: In line with its policy to continually improve its products, Vulcan reserves the right to change materials and specications without notice.
MODEL
NO.
BTU/HR.
INPUT
BRIMFUL
CAPACITY*
4 OZ.
SVGS. A B C D E F G H J K
VGL20 100,000
20 gal., 80 qts.
76 liters
640
20
508
27
1
⁄
2
698
40
1016
32
813
3
76
19
483
64
1626
24
610
30
1
⁄
2
775
6
152
VGL40 100,000
40 gal., 160 qts.
152 liters
1280
26
660
32
1
⁄
2
825
44
1118
38
1
⁄
2
978
2
51
19
483
72
1829
29
737
35
889
6
152
VGL60 130,000
60 gal., 240 qts.
227 liters
1920
30
762
36
1
⁄
2
927
49
1
⁄
2
1257
42
1016
2
1
⁄
2
63
21
1
⁄
2
546
85
2159
35
889
39
991
8
203
* Working capacity 70% to 80% of brimful depending on model.
IMPORTANT:
1. A pressure regulator sized for this unit is included. Minimum
supply pressure: Natural gas 7" W.C. Propane 11" W.C.
2. Gas line connecting to unit must be
3
⁄
4
" or larger. If exible
connectors are used, the inside diameter must be at least the
same as the
3
⁄
4
" iron pipe and rated for the correct gas input.
3. Requires 120 volt, 60 Hz, 1 phase electrical connection.
Furnished with 6' cord and 3 prong plug. 3 amp total draw.
4. An adequate ventilation system is required for commercial
cooking equipment. Information may be obtained by writing to the
National Fire Protection Association, Batterymarch Park, Quincy,
MA 02269. When writing, refer to NFPA No. 96.
5. These units are manufactured for installation in accordance with
ANSZ223.1a (latest edition), National Fuel Gas Code. Copies may
be obtained from the American Gas Association. 1515 Wilson
Blvd., Arlington, VA 22209.
6. Equipment clearance: Combustible Non-Combustible
Rear 2" 2"
Right 6" 6"
Left 6" 6"
7. This appliance is manufactured for commercial installation only
and is not intended for home use.
GS: See #1 & #2 above.
EC: See #3 above.