A SERVICE OF

logo

12
Manifold
a)
c)
b)
d)
Manifold
Figure 22
Manifold
Manifold
Summit 425 or
Summit 450
Figure 22
Summit 625 or
Summit 650
a)
d)
c)
Check:
a) Left valves to manifold connection. Figure 22 (a).
b) Center valves to manifold connection. Figure 22 (b).
(For Summit 625 or 650 only.)
c) Right valves to manifold connection. Figure 22 (c).
d) Gas line to manifold connection. Figure 22 (d)
WARNING: If there is a leak at connection 22 (d), turn
OFF the gas and retighten the fitting with a wrench
and recheck for leaks with soap and water solution.
If a leak persists after retightening the fitting, turn
OFF the gas. DO NOT OPERATE THE BARBECUE.
Contact your dealer.
Check for leaks by wetting the connections with the soap
and water solution and watching for bubbles. If bubbles
form or if a bubble grows there is a leak.
WA R N I N G : D o n o t i g n i t e bu r n e rs when leak ch e ck i n g .
CHECK FOR GAS LEAKS
(CONTINUED)