AEG 2642-6 KG Refrigerator User Manual


 
26
Installation
Installation Location
The appliance should be set up in a well ventilated, dry room.
Energy use is affected by the ambiààent temperature. The appliance
should therefore
Ð not be exposed to direct sunlight;
Ð not be installed next to radiators, cookers or other sources of heat;
Ð only be installed at a location whose ambient temperature corre-
sponds to the climate classification, for which the appliance is desi-
gned.
The climate classification can be found on the serial plate, which is
located at the left on the inside of the appliance.
The following table shows which ambient temperature is correct for
each climate classification: each climate classification:
Climate classification ffor an ambient temperature of
SN +10 bis +32 ¡C
N +16 bis +32 ¡C
ST +18 bis +38 ¡C
T +18 bis +43 ¡C
If installation next to a source of heat is unavoidable, the following
minimum clearances must be maintained at the sides of the applian-
ce:
Ð for electric cookers 3 cm;
Ð for oil and coal fired ranges 30 cm.
If these clearances cannot be maintained a heat insulating pad is
required between the cooker and the refrigeration appliance.
If the refrigeration appliance is installed next to another refrigerator or
freezer a clearance of 5 cm at the sides is required, in order to pre-
vent the formation of condensation on the outside of the appliance.