AEG D4100-1 Double Oven User Manual


 
THINGS TO NOTE
This appliance is designed to be fitted in cabinets of
the recommended dimensions as shown (Fig. 3),
page 41.
If your cabinet interior dimension is between
565-570mm the oven may still be fitted. However, a
minor modification to the cabinet will be required.
The dimensions given provide adequate air
circulation around the unit within the cabinet,
ensuring compliance with BS EN60-335.
Enquiries regarding the installation of the appliance
point if required should be made to your Regional
Electricity Company to ensure compliance with their
regulations.
The appliance socket switch should be outside the
cabinet but within 2m of the appliance to make it
accessible to switch off the appliance in case of an
emergency.
To protect the hands wear gloves when lifting the
oven into its housing.
NOTE: HOUSE CIRCUIT
Earth leakage and continuity tests must be carried out
before the appliance is connected to the mains supply
and re-checked after fitting.
PREPARING CABINET FOR FITTING OF
OVEN
Make sure the cabinet is the correct size for the
appliance to be fitted (Ref. Fig. 3), page 41.
If the size is between 565-570mm, then the cabinet
should be modified so that at the screw fixing points
the recommended dimension of at least 560-565mm
is maintained. The modification should ideally be
localised to ensure that after screw fitment the oven
is securely fixed into position.
The cabinet must be stable and level by firmly
securing it to the wall or floor. If necessary, make
arrangements to ensure the shelf upon which the
oven will rest is level.
When the appliance is installed ensure a minimum
gap of 2mm is maintained between the trim on the
bottom edge of the appliance and any corresponding
door/ panel underneath.
40
Do not lift the appliance by the handles.