AEG DK 4390 Ventilation Hood User Manual


 
57
Charcoal filter
The charcoal filter should only be used if you want to use the hood
in recirculation mode.
Cleaning/replacing the carbon filter
Unlike other carbon filters, the LONGLIFE carbon filter can be
cleaned and reactivated. At normal use the filter should be cleaned
every second month (when using the hood 2,5 hours per day, in
avarage). The best way to clean the filter is in the dishwasher. Use
normal detergent and choose the highest temperature (65º C).
Wash the filter separately so that no food parts gets stuck on the
filter and later causes bad odours. To reactivate the carbon, the filter
should be dried in an oven for 10 minutes with a temperature of
maximum 100º C.
After approximately three years of use, the carbon filter should be
replaced with a new one, as the odour reduction capacity will be
reduced.
Fitting
Remove the grease filters. Remove the frame i which supports the
filter h by turning 90° the two knobs g.
Insert the charcoal filter inside the frame and put all parts back in
their place. Refit the grease filters. Fig. 4.
To remove proceed in the reverse order.
Always specify the hood model code number and serial number
when ordering replacement filters. This information is shown on the
rating plate located on the inside of the unit.
The charcoal filter can be ordered from your local Service Force
Centre.
Fig. 4
g
g
j
h
i
g
g