Technical Details
Model HL 7275
DL 7275
Dimensions:
Height 252 mm
Width 724 mm
Depth 289 mm
Maximum absorbed power: 240 W
Motor absorption: 200 W
Lighting: 2 x 20 W
Electrical connection 220-240 V
Length of the cable: 150 cm
Fuse rating: 13A 250V
Mounting accessories included
8 screws 2,9 x 16
1 Coupling ring (+ 2 screws 3.5 x 9,5)
1 Multiconnector 150-125-120
Electrical connection for UK only
Safety warnings for the electrician
Connect the hood to the mains supply via a double pole switch which
has 3 mm minimum separation between the contacts.
The switch must be accessible at all times.
The following is valid in the United Kingdom only:
- the wire which is coloured green and yellow must be connected to
the terminal which is marked with the letter E or by the earth symbol
( ), or coloured green or green and yellow;
- the wire which is coloured blue must be connected to the terminal
which is marked with the letter N or coloured black, -
- the wire which is coloured brown must be connected to the terminal
which is marked with the letter L or coloured red.