Installation Instructions
Save these instructions for future reference.
F When all connections have been made, make
sure all range controls are in the off position
and turn on the main gas supply valve.
Use a liquid leak detector at all joints and
connections to check for leaks in the system.
Use a product specifi cally manufactured for
leak detection. Leak testing of the appliance
shall be conducted in accordance to the
manufacturer’s instructions.
CAUTION: DO NOT USE A FLAME
TO CHECK FOR GAS LEAKS.
When using test pressures greater than 1/2
psig (3.5kPa) to pressure test the gas supply
system of the residence, disconnect the range
and individual shut-off valve from the gas supply
piping. When using test pressures of 1/2 psig
(3.5kPa) or less to test the gas supply system,
simply isolate the range from the gas supply
system by closing the individual shut-off valve.
Flexible Connector
Installer: Inform the consumer of the location
of the gas shut-off valve.
Electrical Connection
When installed the range must be
electrically grounded in accordance with
local codes or; in the absence of local
codes with the National Electrical Code
ANSI/NFPA 70, latest edition.
In Canada the range must be installed
in accordance with the current CSA
Standard C22.1 - Canadian Electrical Code
Part 1.
Electrical Power Supply
Requirements
Electrical Requirements
CAUTION: FOR PERSONAL SAFETY, DO
NOT USE AN EXTENSION CORD WITH
THIS APPLIANCE. REMOVE HOUSE FUSE
OR OPEN CIRCUIT BREAKER BEFORE
BEGINNING INSTALLATION.
This appliance must be supplied with the proper
voltage and frequency, and connected to an
individual, properly grounded branch circuit,
protected by a circuit breaker or time-delay fuse,
as noted on the rating plate.
Wiring must conform to National Electric Codes.
If the electric service provided does not meet the
above specifi cations, have a licensed electrician
install an approved outlet.
Because range terminals are not accessible
after range is in position, fl exible service conduit
or cord must be used.
Provide Proper Electrical Supply
This range must be supplied with 208/240
volt, 60 Hz., and connected to an individual,
properly grounded branch circuit protected by a
circuit breaker or time-delay fuse (40 amp). The
receptacle must be NEMA 14-50R to accept the
4-prong plug supplied with the range.
If the electrical service provided does not meet
the above specifi cations, it is recommended that
a licensed electrician install an approved outlet.
Locate the electric supply as illustrated.