1. An identification tag is permanently mounted on
the cabinet.
2. Plug cabinet into a properly grounded receptacle
ONLY, positioning the unit so the power supply
cord is easily accessible in case of an emergency.
3. If necessary, a proper receptacle or outlet
configuration as required for this unit, must be
installed by a licensed electrician in accordance with
applicable, local electrical codes.
DANGER
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.
DANGER
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
ELECTRICAL 1000-BQ2/128
voltage phase cycle/hz amps kW cord & plug included
120(agcy) 1 60 17.5 2.1 NeMa 5-20p
20A- 125V plug
208-240(agcy)1 60 8.8 2.1
NeMa 6-15p
208 1 60 7.7 1.6 15A-250Vplug
240 1 60 8.9 2.1
230(agcy) 1 50/60 8.4 2.0 cee 7/7
220-230V plug
ELECTRICAL 1000-BQ2/96
voltage phase cycle/hz amps kW cord & plug included
120 (agcy) 1 60 12.5 1.5 NeMa 5-15p
15A- 125V plug
208-240(agcy)1 60 7.0 1.6 NeMa 6-15p
at208 1 60 5.9 1.2 15A-250Vplug
at240 1 60 6.8 1.6
230(agcy) 1 50/60 6.5 1.5 cee 7/7
220-230V plug
ELECTRICAL CONNECTION
INSTALLATION
Wire diagrams are located inside the top of the unit.
Hard wired models:
Hard wired models must be equipped with a
country certified external allpole disconnection
switch with sufficient contact separation.
If a power cord is used for the connection of the
productanoilresistantcordlikeH05RNorH07RN
or equivalent must be used.
DANGER
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
For CE approved units: To prevent an electrical
shock hazard between the appliance and other
appliances or metal parts in close vicinity, an
equalization-bonding stud is provided. An
equalization bonding lead must be connected to
this stud and the other appliances / metal parts
to provide sufficient protection against potential
difference. The terminal is marked
with the following symbol.
NOTE: CE approved appliances must be
connected to an electrical circuit that is
protected by an external GFCI outlet.
ELECTRICAL 1000-BQ2/192
voltage phase cycle/hz amps kW cord & plug included
120(agcy) 1 60 24.0 2.9 NeMa 5-20p
power switch in low position 16.0 1.9 20A- 125V plug
NeMa 5-30p
power switch in high position 25.0 max 3.0 30A - 125V plug
208-240(agcy)1 60 13.5 3.3 NeMa 6-15p
at 208 1 60 11.8 2.5 15A - 250V plug
at240 1 60 13.6 3.3
230 (agcy) 1 50/60 13.0 3.0 cee 7/7
220-230V plug