Alto-Shaam 1000-BQ2/192 Refrigerator User Manual


 
13
T
he electronic thermostat is a precise
instrument and is designed to offer trouble free
service. If you suspect the temperature inside
the holding compartment does not match the
temperature indicated on the digital display,
follow the instructions listed below.
1. Check to make certain the unit voltage
matches the power source. A power source
less than that required to operate the unit
will result in inaccurate temperatures.
2. Verify the temperature inside the holding
compartment with a qualify thermal
indicator.
A. With the exception of the wire shelves,
completely empty the holding
compartment.
B. Make certain the holding cabinet sensor,
located inside the holding compartment
at the left side of the unit, is completely
clean.
C. Suspend the thermal indicator in the
center of the holding compartment.
D. Allow the temperature set on the
electronic thermostat to stabilize for a
minimum of one hour before comparing
the digital display with the reading on
the thermal indicator.
DO NOT OPEN THE CABINET DOOR(S)
DURING THE TEMPERATURE
STABILIZATION PERIOD.
If the reading on the thermal indicator does not
match the digital display, there may be a
problem with the air sensor. See
troubleshooting guide in
this manual; or call the factory service
department for advice.
T H E R M O S TA T A C C U R A C Y
M A I N T E N A N C E
D A N G E R
DISCONNECT UNIT FROM
POWER SOURCE BEFORE
CLEANING OR SERVICING.