Alto-Shaam 1000-BQ2/96 Refrigerator User Manual


 
1. An identification tag is permanently mounted on
the cabinet.
2. Plug cabinet into a properly grounded receptacle
ONLY, positioning the unit so the power supply
cord is easily accessible in case of an emergency.
3. If necessary, a proper receptacle or outlet
configuration as required for this unit,
must be installed by a licensed electrician
in accordance with applicable, local electrical codes.
NOTE:
230V units:
To prevent an electrical shock hazard
between the appliance and other appliances
or metal parts in close vicinity, an
equalization-bonding stud is provided. An
equalization bonding lead must be connected
to this stud and the other appliances / metal
parts to provide sufficient protection against
potential difference. The terminal is marked
with the following symbol.
The appliance must be connected to an
electrical circuit that is protected by an
external GFCI outlet.
6
I N S T A L L A T I O N
E L E C T R I C A L
D A N G E R
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
D A N G E R
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in according with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.
D A N G E R
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
ELECTRICAL 1000-BQ2/192
VOLTAGE PHASECYCLE/ HZ AMPS kW CORD & PLUG INCLUDED
125 1 50/60 NEMA L5-20P
POWER SWITCH IN LOW POSITION 16.0 2.0 20A- 125V PLUG
POWER SWITCH IN HIGH POSITION
24.0
MAX
3.0 NEMA L5-30P
30A - 125V PLUG
208-240 (AGENCY)150/60 12.5 3.0 NEMA 6-15P
at 208 1 50/60 12.3 2.5 15A - 250V PLUG
at 240 1 50/60 14.2 3.4
230 1 50/60 13.0 3.0
CEE 7/7
220-230V
PLUG
ELECTRICAL 1000-BQ2/128
VOLTAGE PHASECYCLE/ HZ AMPS kW CORD & PLUG INCLUDED
125 1 50/60 18.4 2.30 NEMA 5-20P
20A- 125V PLUG
208-240 (AGENCY)1 50/60 8.3 2.0 NEMA 6-15P
208 1 50/60 7.6 1.6 15A - 250V PLUG
240 1 50/60 8.7 2.1
230 1 50/60 8.4 1.95
CEE 7/7
220-230V
PLUG
ELECTRICAL
V
OLTAGE PHASECYCLE
/ H
Z AMPS
kW C
ORD
& P
LUG INCLUDED
125 1 50/60 12.8 1.6 NEMA 5-15P
15A- 125V PLUG
208-240 (AGENCY)1 50/60 6.5 1.6 NEMA 6-15P
at 208 1 50/60 5.9 1.2 15A - 250V PLUG
at 240 1 50/60 7.0 1.6
230 1 50/60 6.5 1.5
CEE 7/7
220-230V
PLUG