GAS COMBITHERM INSTALLATION MANUAL #MN-28676
PG. 15
INSTALLATION REQUIREMENTS
®
COMBITHERM
The gas Combitherm must use a connector that
complies with The Standard for Connectors for
Movable Gas Appliances, ANSI Z21.69 CSA 6.16
and addenda Z21.69a-1989. A quick disconnect
devise must be installed to comply with The
Standard for Quick Disconnect Devices for Use
with Gas Fuel, ANSI Z21 CSA 6.9.
Adequate means must be provided to limit the
movement of this appliance. Limitation of
movement must be made without depending on
the connector, the quick disconnect device, nor the
associated piping designed to limit appliance
movement. If it becomes necessary to disconnect
the restraint, it must be reconnected immediately
following the return of the appliance to its
original position.
1. Install a manual gas shut-off valve along with an
approved disconnect device.
2. Install an A.G.A. certified, heavy-duty connector
that complies with ANSI Z 21.69 or CAN 1-6.10m88
along with a quick-disconnect device in compliance
with ANSI Z21.41 or CAN 1-6.9m70. Connectors
must be installed with a cable restraint to prevent
excessive tension from being placed on the
connector.
MOBILE EQUIPMENT RESTRAINT
DRIP TRAY INSTALLATION
T
he appliance is shipped without the drip tray
i
nstalled. This must be installed before equipment
o
peration begins.
Position drip tray mounting bracket beneath oven.
Secure with lock washer and phillips screws supplied.
Slide drip tray assembly into mounting bracket.
Secure with lock washer and nut.
Attach drip tray hose to drip tray assembly. Secure the
drain fitting connection with the 19mm clamp. Secure
the drip tray hose connection with the 20mm clamp.
ITEM
N
O
.
PART
N
O
.
PART DESCRIPTION QTY
1 1006674 DRIP TRAY MOUNTING BRACKET 1
2 DRIP TRAY 1
3 HO-27220 DRIP TRAY HOSE 1
W A R N I N G
FAILURE TO PROPERLY INSTALL THE
DRIP TRAY CAN OR WILL CAUSE
MAJOR EQUIPMENT DAMAGE AND
WILL RESULT IN A LEAKAGE
HAZARD THAT CAN CAUSE
PERSONAL INJURY.
W A R N I N G
RISK OF ELECTRIC SHOCK.
Appliance must be secured