Alto-Shaam 2800-SK/III Microwave Oven User Manual


 
PG. 10 767-SK/III, 1767-SK/III, 2800-SK/III INSTALLATION/OPERATION/SERVICE MANUAL
The appliance must be installed by a qualified
s
ervice technician. The oven must be properly
grounded in accordance with the National
Electrical Code and applicable local codes.
Plug the unit into a properly grounded receptacle
ONLY, positioning the unit so that the plug is
easily accessible in case of an emergency. Arcing
will occur when connecting or disconnecting the
unit unless all controls are in the
OFF position.
Proper receptacle or outlet configuration or
permanent wiring for this unit must be installed
by a licensed electrician in accordance with
applicable local electrical codes.
230V:
T
o prevent an electrical shock hazard between
the appliance and other appliances or metal
parts in close vicinity, an equalization-bonding
stud is provided. An equalization bonding lead
must be connected to this stud and the other
appliances / metal parts to provide sufficient
protection against potential difference.
The terminal is marked with the following
symbol.
NOTE: The appliance must be connected to an
electrical circuit that is protected by an
external GFCI outlet.
E L E C T R I C A L C O N N E C T I O N
I N S T A L L A T I O N
ELECTRICAL - 767-SK/III
VOLTAGE PHASE CYCLE/ HZ AMPS kW CORD & PLUG
208-240 (UL)1 60 16.0 3.85
NO CORD
at 208 1 60 15.5 3.21
&
PLUG
at 240 1 60 17.8 4.27
230 1 50 16.0 3.68
CEE 7/7
220-230V
PLUG
ELECTRICAL - 1767-SK/III
VOLTAGE PHASE CYCLE/ HZ AMPS kW CORD & PLUG
208-240 (UL)1 60 32.0 7.70
NO CORD
at 208 1 60 30.9 6.43
& PLUG
at 240 1 60 35.6 8.55
230 1 50 34.1 7.86
NO CORD
& PLUG
D A N G E R
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
D A N G E R
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in according with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.
ELECTRICAL - 2800-SK/III
VOLTAGE PHASE CYCLE/ HZ AMPS kW CORD & PLUG
208 1 60 43.1 8.96 CORD, NO PLUG
208 3 60 27 8.96 NO CORD & PLUG
230 1 50 37.1 8.54 NO CORD & PLUG
D A N G E R
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
1PH
3PH