S E R V I C E
Hot Food Drop-In Well Operation & Care Manual • 16
THERMOSTAT and HEAT LIGHT SEQUENCE
Whenever the thermostat is turned “10,” the heat
indicator light will indicate the power ON/OFF
condition of the heating cable, and consequently, the
cycling of the appliance as it maintains the dialed
temperature. If the light does not illuminate after
normal start-up, the main power source, thermostat,
and/or light must be checked. If the appliance does
not hold the temperature as dialed, the calibration of
the thermostat must be checked. If the appliance fails
to heat or heats continuously with the thermostat
“OFF,” the thermostat must be initially checked for
proper operation. If these items are checked and
found to be in order, a continuity and resistance
check of the heating cable should be made.
SEE CIRCUIT DIAGRAM.
SERVICE PARTS
1 CD-3232 CORDSET, 14/3 SJTOW 125V
2 CD-33882 CORDSET, 230V, 16 AMP
3 CD-33840 CORDSET, 16/3, 250V 15A
4 CD-33367 CORDSET, 12/3, 125V, 30A
5 KN-3473 KNOB, THERMOSTAT
6 LI-3027 LIGHT, INDICATOR, 25OV
7 LI-3951 LIGHT, INDICATOR, 110V
8 SW-33648 SWITCH, ROCKER
9 SW-33923 SWITCH, ROCKER, 230V
10 TT-33461 THERMOSTAT, FAST
11 TT-3713 THERMOSTAT, BEZEL
D A N G E R
DISCONNECT UNIT FROM
POWER SOURCE BEFORE
CLEANING OR SERVICING.
C A U T I O N
THIS SECTION IS PROVIDED FORTHE ASSISTANCE
OF QUALIFIED SERVICETECHNICIANS ONLY AND
IS NOT INTENDED FOR USE BY UNTRAINED OR
UNAUTHORIZED SERVICE PERSONNEL.
11
ttoo 44
5
6
& 7
8
& 9
1111
10
CCaabbllee HHeeaattiinngg RReeppllaacceemmeenntt SSeerrvviiccee KKiittss
110000--HHWW 220000--HHWW 330000--HHWW 440000--HHWW && 550000--HHWW
KKiitt NNuummbbeerr 44887777 44887788 44888800 44888811
Service kit includes:
CB-3045 Cable Heating Element . . . . . .37 ft . . . . . . .67 ft . . . . . . .132 ft . . . . . . . . . . . .144 ft
CR-3226 Ring Connector . . . . . . . . . . . . . .2 . . . . . . . . . .4 . . . . . . . . . .8 . . . . . . . . . . . . . . .12
IN-3488 Insulation Corner . . . . . . . . . . . .8 ft . . . . . . . .8 ft . . . . . . . .8 ft . . . . . . . . . . . . . .8 ft
BU-3105 Shoulder Bushing . . . . . . . . . . . . .2 . . . . . . . . . .4 . . . . . . . . . .8 . . . . . . . . . . . . . . .12
BU-3106 Cup Bushing . . . . . . . . . . . . . . . . .2 . . . . . . . . . .4 . . . . . . . . . .8 . . . . . . . . . . . . . . .12
SL-3063 Insulating Sleeve . . . . . . . . . . . . .2 . . . . . . . . . .4 . . . . . . . . . .8 . . . . . . . . . . . . . . .12
TA-3540 High Temp Electrical Tape . . .1 roll . . . . . .1 roll . . . . . .1 roll . . . . . . . . . . . .1 roll
ST-2439 10.32 Stud . . . . . . . . . . . . . . . . . . .2 . . . . . . . . . .4 . . . . . . . . . .8 . . . . . . . . . . . . . . .12
NU-2215 Hex Nut . . . . . . . . . . . . . . . . . . . . .4 . . . . . . . . . .8 . . . . . . . . .32 . . . . . . . . . . . . . .24