Alto-Shaam 500-s Kitchen Entertainment Center User Manual


 
1. An identification tag is permanently mounted on
the cabinet.
2. Plug cabinet into a properly grounded receptacle
ONLY, positioning the unit so the power supply cord
is easily accessible in case of an emergency.
Arcing will occur when connecting or disconnecting
the unit unless all controls are in the “OFF” position.
3. If necessary, a proper receptacle or outlet
configuration as required for this unit, must be
installed by a licensed electrician in accordance with
applicable, local electrical codes.
For 230V:
To prevent an electrical shock hazard between the
appliance and other appliances or metal parts in
close vicinity, an equalization-bonding stud is
provided. An equalization bonding lead must be
connected to this stud and the other appliances /
metal parts to provide sufficient protection against
potential difference. The terminal is marked with the
following symbol.
NOTE:
230V appliances must be connected to an electrical
circuit that is protected by an external GFCI outlet.
E L E C T R I C A L
I N S T A L L A T I O N
500-S, 750-S, 1000-S, 1000-UP INSTALLATION/OPERATION/SERVICE MANUAL 13.
ELECTRI CAL - 500-S
VOLTAGE PHASE CYCLE
/
HZ AMPS
kW
CORD
&
PLUG
120 (AGCY) 1 60 8.3 1.0 NEMA
5-15
P
,
120 1 60 8.4 1.0
15A-125
V PLUG
208-240 (AGCY) 1 60 4.2 1.0 NEMA
6-15
P
,
at 208 1 60 3.7 .76
15A-250
V PLUG
at 240 1 60 4.2 1.0 (USA ONLY)
230 (AGCY) 1 50 4.1 .95 CEE 7/7,
230 1 50 4.0 .93 220-230V PLUG
ELECTRICAL - 1000-S
VOLTAGE PHASE CYCLE
/
HZ AMPS K
W
CORD
&
PLUG
120 (AGCY) 1 60 8.0 .96 NEMA
5-15
P
,
120 1 60 8.6 1.03
15A-125
V PLUG
208-240 (AGCY) 1 60 4.0 .96 NEMA
6-15
P
,
at 208 1 60 3.7 .78
15A-250
V
at 240 1 60 4.3 1.03 PLUG (USA ONLY)
230 (AGCY) 1 50 3.8 .88 CEE 7/7,
230 1 50 4.1 .95 220-230V PLUG
ELECTRICAL - 1000-UP
VOLTAGE PHASE CYCLE
/
HZ AMPS
kW
CORD
&
PLUG
120 (AGCY) 1 60 16.0 1.9 NEMA
5-20
P
,
120 1 60 16.0 1.9
20A-125
V PLUG
208-240 (AGCY) 1 60 8.0 1.9 NEMA
6-15
P
,
at 208 1 60 6.9 1.4
15A-250
V PLUG
at 240 1 60 8.0 1.9
(
USA ONLY)
230 (AGCY) 1 50 7.7 1.8 CEE 7/7,
230 1 50 7.7 1.8 220-230V PLUG
ELECTRI CAL - 750-S
VOLTAGE PHASE CYCLE
/
HZ AMPS
kW
CORD
&
PLUG
120 (AGCY) 1 60 9.0 1.08 NEMA
5-15
P
,
120 1 60 9.0 1.08
15A-125
V PLUG
208-240 (AGCY) 1 60 4.5 1.08 NEMA
6-15
P
,
at 208 1 60 3.9 .81
15A-250
V PLUG
at 240 1 60 4.5 1.08 (USA ONLY)
230 (AGCY) 1 50 4.3 1.0 CEE 7/7,
230 1 50 4.3 .99 220-230V PLUG
D A N G E R
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
D A N G E R
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in according with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.
H
ard wired models:
H
ard wired models must be equipped with a
country certified external allpole disconnection
switch with sufficient contact separation.
If a power cord is used for the connection of the
product an oil resistant cord like H05RN or H07RN
or equivalent must be used.