Alto-Shaam 500-s Kitchen Entertainment Center User Manual


 
500-S, 750-S, 1000-S, 1000-UP INSTALLATION/OPERATION/SERVICE MANUAL 15.
1. PREHEAT AT 200°F (93°C) FOR 30
MINUTES BEFORE LOADING FOOD.
Push power switch to “ON” position. The power
b
utton will illuminate.
2. Rotate the control knob to 200°F (93°C).
The Set temperature will appear in the Digital
Display and the temperature display light
will illuminate. Press the Temperature Display
Button at any time to display the Actual inside
air temperature .
3. When the inside air temperature reaches the
desired holding temperature, the temperature
display light will turn off.
4. Load the cabinet with hot food only.
The purpose of the holding cabinet is to maintain
hot food at proper serving temperatures. Only
hot food should be placed into the cabinet.
Before loading the unit with food, use a food
thermometer to make certain all food products
are at an internal temperature range of 140° to
160°F (60° to 71°C). All food not within the
proper temperature range should be heated
before loading into the holding cabinet.
5. Check to make certain the cabinet door is
securely closed, and rotate the control knob to
160°F (71°C).
THIS WILL NOT
NECESSARILY
BE THE FINAL SETTING.
The proper temperature range for the food being
held will depend on the type and quantity of
product. Whether or not the door vents should be
open or closed will also depend on the type of
food being held. When holding food for
prolonged periods, it is advisable to periodically
c
heck the internal temperature of each item to
assure maintenance of the proper temperature
range. Reset the holding temperature accordingly.
TO TOGGLE BETWEEN FAHRENHEIT
AND CELSIUS
The factory default is Fahrenheit. To change to
Celsius:
1. With the control OFF (i.e. temperature setting in
the OFF position), press and hold the
Temperature Display button for 5 seconds.
2. The control will show “degC” for 3 seconds to
verify selection and then show the temperature.
(Set Point or Actual, whichever the user has
selected) in ºC.
3. Repeat to toggle to Fahrenheit.
No te : With a p o w er failure, facto ry test, e tc., th e
co ntro l w ill re tain the ºC o r ºF setting se lected by th e
use r wh en po w e r is re sto red .
POWER FAILURE
When power is lost, then resumes, the display will
flash “-AC-” for 4 seconds, then display the set
holding temperature for 4 seconds and will alternate
until acknowledged. To acknowledge, press any key.
This feature will alert you when there is a power
failure, indicating that food safety may be
compromised.
A190
S200
I
o
I
o
On/Off
Power
Switch
Digital
Display
Temperature
Control Knob
Temperature
Display
Button
Temp
Display
Light
O P E R A T I O N
M A N U A L C O N T R O L O P E R AT I O N