ASC-2E & ASC-4E Electric Convection Ovens - Electronic Control • 4
INSTALLATION
30-5/8" (778mm)
8" (203mm)
CAVITY VENT
ELECTRICAL
INLET
3-5/32"
(80,1mm)
9-15/16" (252mm)
ELECTRICAL ENTRANCE
123°
129°
29" (737mm)
CAVITY WIDTH
38" (965mm)
31-1/16" (789mm)
4" (102mm)
ELECTRICAL INLET
54-5/8" (1387mm)
44-1/2" (1130mm)
26-1/2" (673mm)
57-1/2" (1461mm)
30" (762mm)
28-3/16" (715mm)
3-15/16" (100mm)
32-1/8" (815mm)
3-3/8" (86mm)
23-1/4" (590mm)
4-11/16"
(119mm)
1"
(25mm)
21-1/8 (536mm)
3-1/4"
(83mm)
25-7/16 (646mm)
30-1/8" (815mm)
Exhaust
Electrical
2" (51mm)
from bottom
ASC-2E
ASC-4E
72lb(33kg)maximum•45qts(43liters)
Twelve (12): 18" x 26" x 1" full-size sheet pans
6 chrome plated wire shelves with
2 removable side racks and 12 shelf positions
spaced at 1-3/4" (43mm)
27 lb (12 kg)
MAXIMUM
— 17 qts (15 liters)
Nine (9): 18" x 13" x 1" half-size sheet pans
5 chrome plated wire shelves with
2 removable side racks and 9 shelf positions
spaced at 1-5/8" (41mm)
MINIMUM 6 INCH
CLEARANCES FROM
COMBUSTIBLES AND
NON-COMBUSTIBLES
Ne pas installer à
une distance inférirure
à celle indiquée
ci-dessous d'une paroi
en matiére combustible:
Côtés 6 pouches,
Arriére 6 pouches
FOR USE ONLY ON
NON-COMBUSTIBLE
FLOORS.
Doit être utilisé
seulement sur des
planchers non
inflammables.
INTENDED FOR
OTHER THAN
HOUSEHOLD USE.
Destiné à un usage
autre que domestique.
3107173
MINIMUM 6 INCH
CLEARANCES FROM
COMBUSTIBLES AND
NON-COMBUSTIBLES
Ne pas installer à
une distance inférirure
à celle indiquée
ci-dessous d'une paroi
en matiére combustible:
Côtés 6 pouches,
Arriére 6 pouches
FOR USE ONLY ON
NON-COMBUSTIBLE
FLOORS.
Doit être utilisé
seulement sur des
planchers non
inflammables.
INTENDED FOR
OTHER THAN
HOUSEHOLD USE.
Destiné à un usage
autre que domestique.
3107173