Alto-Shaam ASC-2E Convection Oven User Manual


 
ASC-2E & ASC-4E Electric Convection Ovens - Electronic Control • 5
INSTALLATION
The oven must be mounted on the factory equipped
oven legs or on an optional oven stand. Installation
on a solid or concrete base that in any way restricts
air flow may void the warranty.
All clearances for a proper ventilation air supply
must be maintained to minimize fire hazard. Do not
locate the oven immediately adjacent to any other
heat-generating appliance.
A number of adjustments are associated with
initial installation and start-up. Adjustments
must be conducted by a qualified service
technician. Installation and start-up adjustments
are the responsibility of the dealer or user.
These adjustments include but are not limited
to thermostat calibration, door adjustment, and
leveling. The Platinum series oven burners are
factory-adjusted with fixed air openings and require
no field adjustment.
LEVELING
The oven should be leveled before
the gas supply is connected. Level the oven from
side-to-side and front-to-back with the use of a
spirit level. For ovens installed on a mobile stand,
it is important that the floor surface be level due to
the probability of frequent oven repositioning.
We recommend checking the level of the oven
periodically to make certain the floor has not
shifted nor the oven moved.

DANGER
IMPROPER INSTALLATION,
ALTERATION, ADJUSTMENT,
SERVICE, OR MAINTENANCE COULD
RESULT IN SEVERE INJURY, DEATH,
OR CAUSE PROPERTY DAMAGE.
READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING
THIS EQUIPMENT.
CAUTION
TO PREVENT PERSONAL INJURY,
USE CAUTION WHEN MOVING OR
LEVELING THIS APPLIANCE.
RESTRAINT REQUIREMENTS
—MOBILE EQUIPMENT
Any appliance that is not furnished with a power
supply cord but includes a set of casters must be
provided with a tether. Adequate means must be
provided to limit the movement of this appliance
without depending on or transmitting stress to the
electrical conduit. The following requirements apply:
1. Casters must be a maximum height of 6" (152mm).
2. Two of the casters must of be the locking type.
3. Such mobile appliances or appliances on mobile
stands must be installed with the use of a flexible
connector secured to the building structure.
A mounting connector for a restraining device
is located on the lower back flange of the appliance
chassis or on an oven stand, approximately
18" (457mm) from the floor. A flexible connector
is not supplied or available from the factory.
WARNING

Appliance must be secured
to building structure.
Where automatically operated appliances are vented through a ventilating hood or
exhaust system equipped with a damper or with a power means of exhaust, provisions
shall be made to allow the equipment to operate only when the damper is open to a
position to properly vent the appliance and when the power means of exhaust is in
operation.
ACCORDANCE WITH NFPA 54 COMMONWEALTH OF MASSACHUSETTS ONLY.