Alto-Shaam ASC-4G Oven User Manual


 
ASC-4G Gas Convection Oven - Electronic Control • 7
GAS SUPPLY & INSTALLATION
GAS CONNECTION
FOR OVENS ON CASTERS
The oven must be supplied with a flexible
connector that complies with The Standard for
Connectors for Movable Gas Appliances, ANSI
Z21.69, CGA 6.16 and addenda Z21.69a (latest
editions). A quick disconnect device must be
installed to comply with The Standard for Quick
Disconnect Devices for Use with Gas Fuel, ANSI
Z21.41 and CAN1-6.9 (latest editions). A flexible
connector is not supplied by the factory.
Adequate means must be
provided to limit the
movement of the appliance.
Limitation of movement
must be made without
depending on the connector,
the quick disconnect device,
or the associated piping
designed to limit oven
movement. Mounting holes
for a restraining device are
located on the lower back
flange of the oven chassis.
Shut the gas supply
OFF
if it becomes
necessary to disconnect the restraint.
Reconnect the restraint immediately
following the return of the oven to its
original position. Turn the gas supply
ON
after the restraint has been reconnected.
LEAK TESTING
Use a soap and water solution on all gas supply
line connections.
CORRECT
RESTRAINT
DANGER
NEVER USE AN OPEN
FLAME TO LEAK TEST.