Alto-Shaam COMBITHERM COMBINATION Oven / Steamer ES electric combitouch Double Oven User Manual


 
COMBITOUCH® ES SERIES ELECTRIC INSTALLATION MANUAL • 37.
INSTALLATION
VENTLESS HOOD OPTION
TOP LEVEL ASSY, VHES-5 HOOD
FOR COMBI
5010692
TOP EXHAUST VENT
2
6
1
4
3
5 7
1 Ventless Hood Power Knob
2 Emergency Latch Release: This release is to
be used ONLY if the timed latch mechanism is
not working or in the event of a power outage.
Repeated use of the emergency release may
damage the switching mechanism.
3 Indicator Lights: If the indicator lights do
not illuminate, the filters may be missing or
not properly aligned. Check them for proper
positioning. Ventless hood and oven will not
operate unless the hood is closed properly.
4 Combi Reset Button: The reset has to be used
if the Combitherm oven is turned on before the
hood or if the hood was opened. It resets the
pressure switch circuit and provides power to
the Combi control circuit. This switch must also
be used to reset hood controls after any problem
with the filters, or the improper latching of the
ventless hood door.
5 Charcoal Filter: The charcoal filter should be
inspected for contaminant's on a regular basis.
Replacement must be made at a minimum of
three month intervals — more often if heavy
contaminant's are visible or if the filter no
longer controls odors.
To remove the filter, pull and slide out while
holding the bottom housing. When replacing
the filter, make certain the air flow arrow(s)
point toward the hood fan, and that the filter
is replaced in the three-sided metal frame
provided with the hood.
FI-24114 (VHes-5); FI-24102 (VHes-10)
6 Timed Latching Mechanism: In order to
evacuate steam and grease-laden air from the
oven interior, this mechanism prevents the
operator from fully opening the oven door for
25 seconds to one minute. The mechanism
automatically disengages at the end of a pre-set
time allowing full door extension.
7 Grease Filter: Cleaning frequency should be
based on oven usage with a maximum of two
weeks between cleaning if the oven is used for
non-grease laden products or steam applications
only. Grease laden products require cleaning
frequency of at least once a week.
Remove the grease filter by pulling it straight
out of the housing. Place the filter in the
dishwasher or wash separately by placing in
hot, soapy water until all grease and particles
have been removed. Rinse thoroughly. Allow
the filter to air dry before reinstalling.
To replace the grease filter, the air flow arrow
on the filter casing should be pointing toward
the hood fan.
FI-24113 (VHes-5); FI-23062 (VHes-10)
OPERATION
1 Turn the ventless hood
power knob “ON”.
2 Wait ve seconds, then
press the “COMBI
RESET” button.
3 Turn the Combitherm
oven power “ON”.