Alto-Shaam QC-100 Refrigerator User Manual


 
QUICKCHILLER INSTALLATION/OPERATION/SERVICE MANUAL 7.
E L E C T R I C A L
I N S T A L L A T I O N
VOLTAGE PHASE CYCLE/HZ
QC-3 QC-20 QC-40 QC-50 QC-100
SELF-CONTAINED
208-240VAC 1 ph 50/60 Hz
R
ECOMMENDED CIRCUIT AMPERAGE:
R
ECOMMENDED WIRE SIZE:
20 amps
12/2 w.g.
20 amps
12/2 w.g.
30 amps
10/2 w.g.
40 amps
8/2 w.g.
60 amps
6/2 w.g.
NO CORD AND PLUG
VOLTAGE PHASE CYCLE/HZ
QC-3 QC-20 QC-40 QC-50 QC-100
SELF-CONTAINED
208-240VAC 3 ph 50/60 Hz
R
ECOMMENDED CIRCUIT AMPERAGE:
R
ECOMMENDED WIRE SIZE:
NOT AVAILABLE NOT AVAILABLE NOT AVAILABLE
20 amps
12/3 w.g.
40 amps
8/3 w.g.
NO CORD AND PLUG
VOLTAGE PHASE CYCLE/HZ
QC-3 QC-20 QC-40 QC-50 QC-100
REMOTE COMPRESSOR
(Cabinet Only)
208-240VAC 1 ph 50/60 Hz
R
ECOMMENDED CIRCUIT AMPERAGE:
R
ECOMMENDED WIRE SIZE:
NOT AVAILABLE NOT AVAILABLE NOT AVAILABLE
20 amps
12/2 w.g.
30 amps
10/2 w.g.
NO CORD AND PLUG
D A N G E R
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
D A N G E R
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.