Amana ARS8267BS Refrigerator User Manual


 
13
Wate r f i lte r data
GENERAL USE
CONDITIONS
Read this Performance Data Sheet and
compare the capabilities of this
refrigerator with your actual water
treatment needs.
DO NOT use this product where water
is microbiologically unsafe or of
unknown quality without adequate
disinfection before or after the
system. Systems certified for cyst
reduction may be used on disinfected
water that may contain filterable
cysts.
Use only with cold water supply.
Check for compliance with the state
and local laws and regulations.
The Amana
®
Clean ‘n Clear™ retractable
water filtration system uses a WF50
replacement cartridge. Timely
replacement of filter cartridge is
essential for performance satisfaction
from this filtration system. Please refer to
the applicable section in this Owner’s
Manual for general operation,
maintenance requirements and trouble
shooting.
This system has been tested according
to ANSI/NSF 42 and 53 for reduction of
the substances listed below. The
concentration of the indicated
substances in water entering the system
was reduced to a concentration less than
or equal to the permissible limit for water
leaving the system, as specified in
ANSI/NSF 42 and 53.
*Tested using a flow rate of 0.75 GPM (2.83 L/min.) and a maximum pressure of 120 psi (827 kPa) under
standard laboratory conditions, however, actual performance may vary. Health Claim Performance tested
and certified by NSF International
** Particle size range classification of test. Particles used were 0.5 –1 microns.
Influent Challenge Effluent Average % Maximum Min. Required Inlet
Substance Concentration Average Reduction Effluent Reduction pH
Lead 0.15 mg/L +/- 10% 0.001 mg/L 99.33% 0.001 mg/L 0.010 mg/L 6.5
Lead 0.15 mg/L +/- 10% 0.002 mg/L 98.66% 0.003 mg/L 0.010 mg/L 8.5
Cyst Minimum 50,000/L 1count/mL 99.99% 3 count/mL > 99.95% NA
Turbidity 11+/-1 NTU 0.12 NTU 98.98% 0.18 NTU 0.5 NTU NA
Lindane 0.002 mg/L +/- 10% 0.00005 mg/L 97.62% 0.00005 mg/L 0.00002 mg/L NA
Atrazine 0.009 mg/L +/- 10% 0.0002 mg/L 97.93% 0.0006 mg/L 0.003 mg/L NA
Chlorine 2.0 mg/L +/- 10% 0.09 mg/L 95.26% 0.17 mg/L 75% NA
Particulate** at least 10,000 900 count/mL 99.68% 2400 count/mL 85% NA
particles/mL
2,4-D 0.210 mg/L +/- 10% 45.45 ug/L 84.42% 100 ug/L 0.0017 mg/L NA
Asbestos
10
7
to 10
8
fibers/L; fibers greater
0.16 MFL/mL 99.96% 0.16 MFL/mL 99% NA
than 10 micrometers in length
PERFORMANCE DATA
SYSTEM SPECIFICATION AND
PERFORMANCE DATA SHEET
REFRIGERATOR WATER FILTER
CARTRIDGE MODEL WF50
Specifications
Service Flow Rate (maximum)...............................................0.75 GPM (2.83 L/min)
Rated Service Life WF50-NI300 (maximum) .........................300 gallons/1135 liters
Rated Service Life WF50-WI500 (maximum).........................500 gallons/1892 liters
Maximum Operating Temperature..........................................100° F/38° C
Minimum Operating Temperature...........................................33° F/1° C
Minimum Pressure Requirement............................................35 psi/138 kPa
Maximum Operating Pressure................................................120 psi/827 kPa
1000 Apollo Road
Eagan, Minnesota U.S.A.
EPA EST #35917-MN-1
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead, Atrazine, Lindane and 2, 4-D Reduction
Mechanical Filtration Unit
Cyst, Turbidity and Asbestos Reduction
Tested and certified by NSF International against ANSI/NSF Standards 42 and 53 in
models WF50-WI300 and WF50-NI500 for the reduction of:
Standard No. 42: Aesthetic Effects
Taste and Odor Reduction
Chlorine Reduction
Mechanical Filtration Unit
Particulate Reduction Class 1