3 Installaton
The cooker hood must be installed centrally
over a cooking appliance. The minimum distance
between the cooking surface and the metal
grease filters on the underside of the hood must
be at least 650mm.
To install the hood proceed as follows:
1. Drill six 8mm diameter holes at X1-X2-J and
insert the plastic rawl plugs supplied as
illustrated in fig. 2 ensuring the brackets are
fitted as shown in the blow up.
2. Secure the two brackets C to the wall inserting
two of the screws supplied through the two
holes on line X1-X2 as illustrated in fig. 2.
3. Slide the canopy down the wall to locate the key
hole over the washer then secure the canopy to
the wall by inserting two of the screws supplied
through the two outer holes in the rim of the
canopy J1 and J2 as illustrated in fig. 3.
4. EXTRACTION OR RECIRCULATION
INSTALLATION:
EXTRACTION (DUCTED)
When installing the ducted version, connect the
hood to the chimney using either a flexible or rigid
pipe ø 150 or 120 mm, the choice of which is left
to the installer.
To install a ø 120 mm air exhaust connection,
insert the reducer flange 9 on the hood body
outlet.
Fix the pipe in position using sufficient pipe
clamps (not supplied).
Remove any activated charcoal filters.
RECIRCULATION (FILTERED)
When the hood is fitted in the recirculation
mode the Air Outlet Connection H should be fit-
ted as illustrated in fig. 6.
Fit the (optional) charcoal filters by repeating
the following operation on each side of the
motor housing. Place the two key hole slots in
the filter L and turn the filter clockwise to lock
the filter in position as illustrated in fig. 7.
WARNING: It is a possible fire hazard if the metal
grease filters are not cleaned and the charcoal
filters replaced regularly.
Fttng The Chmney
5. Fitting the Chimney upper
To fit the upper chimney A, place the top edge
of the chimney over the bracket C as illustrated
in fig. 8 and secure the chimney using two of
the 2.9mm self tapping screws provided. The
distance H in the height between the fixing
holes X1 and X2 is determined by the height of
the upper chimney A.
6. FITTING THE CHIMNEY LOWER
To fit the lower chimney B, apply slight force to
the two rear edges to increase the width of the
apperture, then sleeve the chimney B over the
chimney A as illustrated in fig. 9.