GAS CONVERSION
WARNING!
Before carrying out this operation, disconnect
the appliance from gas and electricity.
Gas conversion shall be conducted by a factory
trained professional.
Call the customer service hotline to identify a
factorytrained professional near your home.
The gas conversion procedure for this range
includes 6 steps:
1. Pressure regulator
2. Surface burners
3. Main oven burner
4. Broiler burner
5. Visual checks prior to closure of oven bottom
panel
6. Adjustment of minimum setting
The conversion is not completed if all 6 steps
have not been concluded properly.
Before performing the gas conversion, locate the
package containing the replacement nozzle
shipped with every range. IMPORTANT: Each
nozzle has a number indicating its flow diameter
printed on the body. Consult the table on page 20
for matching nozzles to burners.
Save the nozzles removed from the range for
future use.
STEP 1: PRESSURE REGULATOR
The pressure regulator supplied with the
appliance is a convertible type pressure regulator
for use with Natural Gas at a nominal outlet
pressure of 4” w.c. or LP gas at a nominal outlet
pressure of 11” w.c. and it is prearranged from
the factory to operate with one of these
gas/pressure as indicated in the labels affixed on
the appliance, package and Instruction booklet.
To convert the regulator for use with other liquid
propane LP gas:
1. Unscrew by hand the upper cap of the
regulator, remove the white plastic
attachment from the cap, reverse its
direction and screw it again firmly against the
cap. The white plastic attachment has arrows
indicating the position for natural gas (NAT)
and LP gas (LP).
2. Screw by hand the metal cap in the original
position on the regulator.