Bertazzoni H48 6G GGV VI Range User Manual


 
13
Follow the instructions below to change the broiler burner nozzle:
1) Loosen the screw and pull out the burner from the support being careful not to damage the ignition plug and the
thermocouple (Fig. 11).
2) Unscrew the nozzle C (Fig. 11) using a 7 mm spanner and replace it with the nozzle needed for the new type of gas
according to what is indicated in TABLE shown below.
Fig. 11
Models MTYKQZV4(L,N,D)(2, 5)A
Adapting to different types of gas
Burner Position Injector Gas Pressure Max Rate Min Rate By-pass
diam. [mm.] Type [i.w.c.] [BTU/h] [W] [BTU/h] [W] diam. [mm]
Auxiliary Front R 0,90 NG 4” 3400 996 900 264 Regulated
0,54 LP (Propane) 11” 3400 996 900 264 0,29
Semi-Rapid Rear L & C 1,18 NG 4” 6100 1787 1500 439 Regulated
Front C 0,70 LP (Propane) 11” 6100 1787 1500 439 0,36
Rapid Rear R 1,55 NG 4” 10400 3047 2500 732 Regulated
0,92 LP (Propane) 11” 10400 3047 2500 732 0,47
Front L Inner 0,80 NG 4” 2800 820 900 264 Regulated
Dual Burner 0,49 LP (Propane) 11” 2800 820 900 264 0,29
Front L Outer N°2 x 1,15 NG 4” 12000 3516 4500 1318 Regulated
N°2 x 0,70 LP (Propane) 11” 12000 3516 4500 1318 0,65
Oven Oven Left 1,85 NG 4” 14500 4248 3500 1025 Regulated
(left cavity) downside 1,10 LP (Propane) 11” 14500 4248 3500 1025 0,54
Broiler Oven Left 1,70 NG 4” 12000 3516 Only Max Only Max No by-pass
(left cavity) upside 0,98 LP (Propane) 11” 12000 3516 Only Max Only Max No by-pass
Oven Oven Right 1,25 NG 4” 7000 2051 2400 703 Regulated
(right cavity) downside 0,75 LP (Propane) 11” 7000 2051 2400 703 0,48
CAUTION: save the orifices removed from the appliance for future use