Bertazzoni PRO30 4 GAS NE Range User Manual


 
7
BEFOREINSTALLATION
This appliance shall only be installed by an
authorizedprofessional.
This appliance shall be installed in accordance
withthemanufacturer’sinstallationinstructions.
This appliance mustbe installedin accordance
withthenorms&standardsofthecountrywhere
it will be installed. The installation of this
appliance must conform to local
codes and
ordinances. In the abs ence of local codes,
InstallationsmustconformstoAmericanNational
Standards,NationalFuelGasCodeANSIZ223.1
latestedition**orB149.1.
The appliance, when installed, must be
electrically grounded in accordance with local
codesor,intheabsenceoflocalcodes,withthe
National
ElectricalCode,ANSI/NFPA70.
Iflocal codespermit,a flexiblemetalappliance
connectionwiththenewAGAorCGAcertified
design, max. 5 feet (1,5 m) long, ½” I.D. is
recommended forconnecting this applianceto
the gassupply line.Do not bend or damagethe
flexibleconnectorwhenmovingthe
appliance.
Thisappliancemustbeusedwiththepressure
regulator pr ovided. The regulator shall be
properlyinstalledinordertobeaccessiblewhen
theapplianceisinstalledinitsfinallocation.The
pressureregulatormustbesetforthetypeofgas
tobeused.Thepressurer egulatorhas½”
female
pipe thread. The appropriate fitting must be
determinedbasedonthesizeofyourgas supply
line,theflexiblemetalconnectorandtheshutoff
valve.
The appliance must be isolated from the gas
supply piping system by closing its individual
manualshutoffvalveduringanypressuretesting
ofthegas
supplypipingsystemattestpressures
equaltoorlessthan½psi(3.5kPa).
Allopeningandholes inthewall andfloor,back
andundertheapplianceshallbesealedbefore
installationoftheappliance.
Amanualvalveshallbeinstalledinanaccessible
locationinthegas
lineexternalto theappliance
forthepurposeofturning onorshuttingoffgas
totheappliance
WARNING!
Donotuseaerosolspraysinthevicinityofthis
appliancewhileitisinoperation
ROOM VENTILATION: An exhaust fan may be
used withthe appliance; ineach caseit
shall be
installed in conformity with the appropriate
national and local standards. Exhaust hood
operationmayaffectotherventedappliances;in
eachcase itshallbe installedin conformitywith
theappropriatenationalandlocalstandards.
TYPEOFGAS
Thisapplianceisshippedfromthefactoryforuse
with propane
lp gas. Foruse with natural gas
please follow the conversion procedure
describedonpg.15.Astepbystepconversion
procedureisalsoincludedwitheachsetoflpgas
nozzles.
GASPRESSURE
Themaximuminletgassupplypressureincoming
to thegas appliance pressureregulator is 20’’
water
column(5kPa).
Theminimumgassupplypressureforchecking
theregulatorsettingshall beatleast1“w.c.(249
Pa)abovetheinletspecifiedmanifoldpressureto
the appliance (this operating pressure is 4” w.c. 
(1.00kPa)forNaturalGasand11”w.c.(2.75kPa
forLPGas).