Bertazzoni X365GGVGI Range User Manual


 
20
Models X366GGVX (X36 6 00 X) [M3Y0GTU4X(2 or 5)A]
Burner Position Injector Gas Pressure Max Rate Min Rate Bypass
diam. [mm.] Type [i.w.c.] [BTU/h] [W] [BTU/h] [W] diam. [mm]
Auxiliary Front R 0,90 NG 4” 3400 996 900 264 Regulated
0,54 LP (Propane) 11” 3400 996 900 264 0,29
SemiRapid Rear L & C 1,18 NG 4” 6100 1787 1500 439 Regulated
Front C 0,70 LP (Propane) 11” 6100 1787 1500 439 0,36
Rapid Rear R 1,55 NG 4” 10400 3047 2500 732 Regulated
0,92 LP (Propane) 11” 10400 3047 2500 732 0,47
Front L Inner 0,80 NG 4” 2800 820 900 264 Regulated
Dual Burner 0,49 LP (Propane) 11” 2800 820 900 264 0,29
Front L Outer N°2 x 1,15 NG 4” 12000 3516 4500 1318 Regulated
N°2 x 0,70 LP (Propane) 11” 12000 3516 4500 1318 0,65
Oven Oven 2,00 NG 4” 16000 4688 4000 1172 Regulated
downside 1,15 LP (Propane) 11” 16000 4688 4000 1172 0,60
Broiler Oven 1,90 NG 4” 14500 4248 Only Max Only Max No bypass
upside 1,10 LP (Propane) 11” 14500 4248 Only Max Only Max No bypass
Models X365GGVX (X36 5 00 X) [M3W0GTU4X(2 or 5)A]
Burner Position Injector Gas Pressure Max Rate Min Rate Bypass
diam. [mm.] Type [i.w.c.] [BTU/h] [W] [BTU/h] [W] diam. [mm]
Auxiliary Front R 0,90 NG 4” 3400 996 900 264 Regulated
0,54 LP (Propane) 11” 3400 996 900 264 0,29
SemiRapid Rear L and R 1,18 NG 4” 6100 1787 1500 439 Regulated
0,70 LP (Propane) 11” 6100 1787 1500 439 0,36
Rapid Front L 1,55 NG 4” 10400 3047 2500 732 Regulated
0,92 LP (Propane) 11” 10400 3047 2500 732 0,47
Centre Inner 0,80 NG 4” 2800 820 900 264 Regulated
Dual Burner 0,49 LP (Propane) 11” 2800 820 900 264 0,29
Centre Outer N°2 x 1,15 NG 4” 12000 3516 4500 1318 Regulated
N°2 x 0,70 LP (Propane) 11” 12000 3516 4500 1318 0,65
Oven Oven 2,00 NG 4” 16000 4688 4000 1172 Regulated
downside 1,15 LP (Propane) 11” 16000 4688 4000 1172 0,60
Broiler Oven 1,90 NG 4” 14500 4248 Only Max Only Max No bypass
upside 1,10 LP (Propane) 11” 14500 4248 Only Max Only Max No bypass