Best EB9 Ventilation Hood User Manual


 
2
READ AND SAVE THESE INSTRUCTIONS
WARNING
5. When cutting or drilling into wall, or ceil-
ing, do not damage electrical wiring or
other hidden utilities.
6. Ducted fans must always be vented to
the outdoors.
7. To reduce risk of fire, use only metal
ductwork.
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not
use to exhaust hazardous or explosive
material and vapors.
2. To avoid motor bearing damage and
noisy and/or unbalanced impellers, keep
drywall spray, construction dust, etc. off
power unit.
3. Please read specification label on prod-
uct for further information and require-
ments.
4. Electrical circuit, including speed con-
trol, (if used), must be rated 6 AMPS
minimum for Model EB9 or 3 AMPS
minimum for Model EB6.
WARNING
TO REDUCE THE RISK OF FIRE, ELEC-
TRIC SHOCK, OR INJURY TO PER-
SONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended
by the manufacturer. If you have ques-
tions, contact the manufacturer at the
address or telephone number listed in
the warranty.
2. Before servicing or cleaning unit, switch
power off at service panel and lock the
service disconnecting means to prevent
power from being switched on acciden-
tally. When the service disconnecting
means cannot be locked, securely fasten
a prominent warning device, such as a
tag, to the service panel.
3. Installation work and electrical wiring must
be done by a qualified person(s) in accor-
dance with all applicable codes and stan-
dards, including fire-rated construction
codes and standards.
4. Sufficient air is needed for proper com-
bustion and exhausting of gases through
the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the
heating equipment manufacturer's guide-
line and safety standards such as those
published by the National Fire Protection
Association (NFPA), and the American
Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE),
INSTALLER: Leave This Manual With The Homeowner.
HOMEOWNER: Use And Care Information On Page 4.
SPECIFICATIONS
MODEL VOLTS AMPS CFM DUCT SIZE
EB6 120 2.4 600 10 " DIA.
EB9 120 5.7 900 10" DIA.
PLAN THE INSTALLATION
1. Locate the blower so the length of the
duct run and number of elbows are kept
to a minimum.
2. Where possible, blower should be cen-
tered between wall studs or roof rafters.
ALL INSTALLATIONS
PLAN THE INSTALLATION
3. Avoid pipes, wires, or other ductwork that
may be running through the wall.
4. Attach mounting plate to top of hood.
5. Install 10” dia. ductwork and 120 VAC
house wiring between blower location
and hood location.