Beverage-Air VM18 Refrigerator User Manual


 
•••• www.beverage-air.com Pg. 5 ••••
ELECTRICAL REQUIREMENTS
The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a
standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this
appliance.
VM units require a dedicated outlet with the following type of receptacle:
VM 2/7 - 5-15R
VM 12/18 - 5-20R
The use of extension cords is not permitted and will void the warranty.
Model
Voltage
(V)
Current
(A)
Circuit
Required (A)
VM2
120
4
15
VM7
120
8
15
VM12
120
11
20
VM18
120
16
20
Before connecting your equipment, check that the electrical data on the data plate match your electrical
output.
IMPORTANT NOTICE: PLUG THE EQUIPMENT INDEPENDENTLY TO A LOAD CENTER WITH AN
APPROPRIATE CIRCUIT BREAKER ACCORDING TO THE NAMEPLATE AMPS.
POSITIONING SHELVES
The shelves and holders have been fixed to the inside floor of the unit to prevent their loss during
transportation.
Insert the shelf brackets in the pilaster notches making sure they are at the same level such that the
shelves remain horizontal.
IMPORTANT: The products on each shelf must leave three to five centimeters of free clearance
between them and the next shelf in order to allow proper air circulation.
PRODUCT LOADING
The VM series of units are not intended to be a pull down refrigerator and as such the product must be
loaded at their intended merchandising temperature.
Before loading products, allow the equipment to operate empty for at least two hours.