COMPRESSORS:
The VM2, and VM7 has a single hermetic compressor. The VM12 and VM18 each have two hermetic
compressors that start in two steps with a delay of 10 seconds to reduce the in-rush of current to the unit.
CONDENSERS:
The VM 7, 12, and 18 units incorporate a "maintenance free" condenser design in the refrigeration
system which reduces the need for the regular cleaning process that fin and tube condensers require.
Besides the savings in preventive maintenance costs, energy expenses will be stable throughout long
periods of time since the condensers will remain "clean and unobstructed". The VM2 condenser
requires frequent cleaning similar to most commercial refrigerators.
EVAPORATOR:
In the event it is believed that the unit has had a “freeze up” condition due to operation of the unit in
high temperature or humidity conditions the evaporator can be inspected by removing the floor of the
inside of the unit. In the event the evaporator is frozen, it can be thawed by emptying the cabinet of
product and removing power until the coil is clear.
CONDENSATION EVAPORATOR TRAY:
When the equipment operates, condensed water from the environment is collected on the evaporator.
During each off-cycle, the water drains to the evaporator tray located at the bottom of the unit where it is
evaporated using the heat from the refrigeration system.
SLIDING CONDENSING UNIT:
The condensing unit can be pulled out, sliding it approximately 40 cm (16") to allow servicing the
condenser motor(s), compressor(s) and electrical components. In order to service the condensing unit,
remove the two screws that hold the lower front grill (one at each side). Remove the screws that hold the
front bracket that clasps the condensing unit and slide it gently out to have access to the components you
want to check.
Once completed, every component must be returned to its original location for proper operation.
LIGHTING:
The lamp can be turned off with the switch located at the left side of the upper section, near the lamp.
NIGHT CURTAIN:
The night curtain should be pulled closed whenever the unit is not required for the active merchandising
of product.