Blodgett SN-5G Oven User Manual


 
4
1.0 SERVICE CONNECTIONS – SN-5G
M
I
N
.
4
[
1
0
2
]
16 [406]
1 [25]
1.75 [44]
4 [102]
40.38 [1026]
5 [127]
12 [305]
SAFETY RELIEF
VALVE
23.19 [589]
G
C
D
16.75 [425]
32 [813]
9 [229]
1.12 [29]
24 [610]
5.25 [133]
1.75 [44]
3 [76]
SAFETY RELIEF
VALVE
3.50 [89]
C
G
D
DIMENSIONS ARE IN INCHES [MM].
C
G
D
FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY.
Water which fails to meet these standards should be treated by installation of water conditioner.
local water treatment specialist and have the water analyzed. Your water supply must be within these general guidelines:
Water quality is the major factor affecting the performance of your appliance. If you are unsure of water quality, consult a
WATER QUALITY STATEMENT
Total dissolved solids
pH Factor
Chlorine
Silica
Total alkalinity
Less than 1.5 PPM
Less than 13 PPM
Less than 20 PPM
7.0-8.5
Less than 60 PPM
Unless otherwise specified, Field Wire Electrical Connection to be 120 Volts, 60 Hertz single phase with grounding wire. Furnished with 6 foot cord
with 3 prong plug. Maximum amps 2.0.
DRAIN: 1"IPS piped to open floor drain. No Solid Connection. 24" length before open air gap opening. (No bends or elbows)
GAS CONNECTION: 3/4"IPS supply line required.
GENERATOR WATER: 3/8" O.D. tubing at 25-50 PSI(170-345 kPa)
CONDENSING WATER: 3/8" O.D. tubing at 25-50 PSI(170-345 kPa)
GAS SUPPLY
6.0-13.8"(150-350mm) 11.0-13.8"(280-350mm)
45,000
13.2
SUPPLY PIPE PRESSURE (W.C.)kW/HR.
MODEL
BTU/HR.
Natural Propane
SN-5G