Bloomfield 0412 Coffeemaker User Manual


 
TROUBLESHOOTING SUGGESTIONS
SUGGESTED REMEDY
Check power supply cord
Check / reset circuit breaker
Set for desired temperature
Allow to cool hi-limit will self-
reset
Examine wiring & connectors,
thermostat and heating element
Repair/replace as needed
Adjust timer
Use one (1) genuine Bloomfield
filter per brew
Thoroughly clean brew
chamber
Use correct grind and amount
of coffee
Check/reinstall gasket on
INSIDE of brew head
Clean spray disk
Check brew switch, timer,
controller, solenoid and wiring
Repair, replace as needed
Turn water supply ON
Clean strainer
Replace filter element
Turn faucet valve ON
POSSIBLE CAUSE
Brewer unplugged or circuit
breaker tripped
Temperature setpoint too low
Hi-Limit safety switch tripped
Damaged internal component
or wiring
Timer out of adjustment
Too many filter papers or wrong
filter paper
Brew chamber dispense hole
plugged
Too much coffee or too fine a
grind
Spray gasket improperly
installed
Spray disk plugged
Damaged internal component
or wiring
Water supply OFF
Solenoid inlet strainer plugged
Water filter (if used) plugged
Faucet valve turned OFF
SYMPTOM
Water won’t heat
Coffee level too high or low
Brew chamber overflows
Sprays water from brew head
No brew (faucet flows OK)
No brew plus no flow from hot
water faucet
No flow from hot water faucet
Poor coffee quality
Keep brewer, decanters and airpots clean.
Install a taste and odor filter in water supply, and replace
cartridges regularly.
Use a quality coffee with a consistent roast. Use proper grind
and amount of coffee per brew.
11
685 77110 Owners Manual Horizon™ Brewers