Bloomfield 8542-D1 Coffeemaker User Manual


 
SERVICING INSTRUCTIONS
ACCESS PANELS
Each warmer plate has a center stud which screws into a
bracket. Warmer plates on Canadian brewers are secured with
a nut. Remove button plug on bottom of brewer to access nut
on warmer plate. Remove warmer plates by turning counter-
clockwise.
Solenoid door is held by two screws and a retaining lip.
Front Panel (In-Line Models) and Top / Rear Panel (3-Station
Models):
a. Remove warmer plate by turning counter-clockwise
until it unscrews.
b. Remove screws from two retaining clips under
warmer plate.
c. Lift off panel.
Front Panel (3-Station Models):
a. Remove warmer plates by turning counter-clockwise
until they unscrew.
b. Remove screws from two retaining clips under each
warmer plate.
c. Remove three screws from bottom-side of front lip.
d. Pull bottom of panel forward until it clears.
Top Panel (All Models):
a. Remove two screws from rear of top panel.
b. Lift rear of panel, remove to rear.
CAUTION:
SHOCK HAZARD
Opening access panels or
removing warmer plates on this
brew may expose uninsulated
electrical components.
Disconnect brewer from
electrical power before
removing any panel or warmer
plate.
Fig. 9 Access Panels
11
M611 75804 Owners Manual Koffee-King™ Brewers