SERVICING INSTRUCTIONS
15
TEMPERATURE ADJUSTMENT
Unplug power cord or turn circuit breaker OFF. Remove top
panel.
Pull vent tube out of tank lid and insert a thermometer of known
accuracy in hole. Reconnect brewer to electrical power.
Place empty container under brew chamber. Energize brewer
and allow unit to heat. When the READY TO BREW light first
glows, read the temperature displayed on thermometer.
Adjust thermostat by turning shaft; clockwise increases
temperature. 1/8 turn = approximately 10ºF, or 5.6ºC.
Refer to Table 1 below for proper brewing temperature based on
altitude.
Upon completion, remove thermometer and reinstall the vent line
and top panel.
Fig. 10 Checking and Adjusting Brew Temperature
CAUTION
Electric Shock
Hazard
These procedures involve
exposed electrical circuits.
These procedures are to be
performed by qualified
technical personnel only.
NOTE: Optimum brewing
temperature is 195ºF to 205ºF
(90ºC to 96ºC).
Thermostat should be adjusted
to a maximum temperature of
200ºF (95ºC).
IMPORTANT:
A mechanical thermostatwill
maintain temperature within
±5ºF.
To prevent boiling water in the
brewer, controller should be
adjusted to a maximum
temperature equal to the local
boiling temperature minus 5ºF,
or 200ºF (94ºC), whichever is
less.
NOTE: 1/8 turn = approximately
10ºF (5.6ºC).
Table 1 Boiling Temperature by Altitude
ELEVATION (feet above seal level)
0
500
1
,0
0
0
1
,
500
2
,
000
2,500
3
,000
3
,500
4,000
4,5
00
5,
000
5,5
00
6,0
00
6
,
500
TEMP. (ºF)
195
200
205
210
190
IDEAL
BREWING
TEMPERATURE
MAXIMUM
TEMPERATURE
SETTING
BOILING
POINT OF
WATER
ELEVATION (meters above seal level)
0
1
5
0
3
00
450
600
75
0
90
0
1
.0
5
0
1.2
0
0
1.350
1.5
00
1.6
50
1.
800
1
.
950
TEMP. (ºC)
91
94
97
100
88
IDEAL
BREWING
TEMPERATURE
RANGE
MAXIMUM
TEMPERATURE
SETTING
BOILING
POINT OF
WATER
Fig. 11 Adjust Thermostat
M628 76201 Owners Manual 8781A Tea Brewer