Bloomfield 8781A Coffeemaker User Manual


 
IMPORTANT: Water pressure
must be between 20 p.s.i and
90 p.s.i. flowing pressure.
If water pressure exceeds this
value, or if water pressure
varies greatly, a pressure
regulator must be installed in
the water supply line.
IMPORTANT: Before setting
assembly into tank, make sure
tank lid gasket is properly
seated on flange of lid.
IMPORTANT: When mounting
thermostat, be sure a new seal
washer is placed below the
fitting on the capillary line.
Push sensing bulb thru tank lid
until fitting seats.
Tighten capillary lock nut only
enough to ensure no water
leakage. Excessive tightening
is not necessary.
IMPORTANT: When replacing
heating element, also replace
seal gaskets.
SOLENOID TIME ADJUSTMENT
The amount of water dispensed automatically during a brew cycle
is controlled by the timer. This adjustment must be performed in
the COFFEE mode.
Place empty decanter under brew chamber. Press BREW
switch. Brewer should dispense one full decanter of water. To
adjust amount:
Remove brew chamber and button plug. Adjust timer; clockwise
increases time. Run several cycles to check amount of water
delivered. Replace button plug.
REMOVE TANK LID ASSEMBLY
Unplug brewer or turn circuit breaker OFF. Turn OFF water
supply. Remove top panel.
Disconnect brew fill and outlet tubes from tank lid fittings.
Disconnect faucet supply and outlet tubes from flare fittings on
tank lid.
Disconnect all wiring from thermostat, hi-limit and heating
element.
Loosen center screw on tank hold-down bracket. Remove
hold-down bracket by sliding short slotted end off of locking stud
and lifting it off. Remove cover assembly by lifting it straight up.
Reassemble in reverse order.
REPLACE THERMOSTAT
Unplug brewer or turn circuit breaker OFF. Turn OFF water
supply. Remove top panel.
Disconnect all wiring from thermostat only. Loosen and free jam
nut from pass-thru fitting securing temperature sensing bulb.
Remove two screws holding thermostat to bracket.
Lift out thermostat, sensing bulb and thermostat gasket.
Reassemble in reverse order.
REPLACE HEATING ELEMENT
Remove tank lid assembly per above.
Remove two hex nuts holding element to cover. Pull element
from mounting holes.
Reassemble in reverse order.
Fig. 12 Adjust Solenoid Time
SERVICING INSTRUCTIONS (continued)
16
M628 76201 Owners Manual 8781A Tea Brewer