Bloomfield 8785 Coffeemaker User Manual


 
SERVICING INSTRUCTIONS (continued)
14
REPLACE SOLENOID
Symptom: Automatic brewer will not flow water; or,
automatic brewer drips continuously from brew head.
Unplug power cord or turn circuit breaker OFF. Turn OFF and
disconnect water supply from brewer inlet fitting.
Unscrew water inlet fitting from solenoid.
Remove two screws holding access door in place. Remove two
screws holding solenoid to door.
Disconnect wiring from solenoid.
Slide the 7/16" end of the wrench between the valve body and
the white ring on the extreme end of the metal hose fitting.
Pressure on the white ring toward the metal ferrule releases the
clinch ring, allowing the hose to be easily slid off of the solenoid
bypass outlet.
Transfer solenoid bracket to new solenoid.
Reinstall hose by pressing end of hose onto bypass outlet until it
is fully seated.
Reassemble in reverse order.
CLEAN SOLENOID SCREEN (NEW-STYLE)
Symptom: Automatic brewer will not flow water.
Unplug power cord or turn circuit breaker OFF. Turn OFF and
disconnect water supply from brewer inlet fitting.
Unscrew water inlet fitting from solenoid.
Using needle-nose pliers, withdraw strainer screen from solenoid.
Clean screen under faucet. A stiff bristle brush may be used if
necessary.
Reinsert screen in solenoid. Be careful to maintain correct
orientation. (The OPEN END of the screen goes in FIRST.)
Reassemble in reverse order.
Fig. 12 Clean Strainer Screen
Fig. 11 Remove Faucet
Supply from Solenoid
622 75854 Owners Manual Gourmet 1000 Airpot/Thermal