Bloomfield 9104A Coffeemaker User Manual


 
5
INSTALLATION INSTRUCTIONS
INSTALL LEGS
The brewer is provided with adjustable legs. Be sure all four legs
are securely screwed into the base of the brewer.
LEVEL THE UNIT
The adjustable legs allow the brewer to be leveled. Set the brewer
in its ultimate operating location and check for level with a spirit
level Adjust the brewer for level from front-to-rear, and from side-
to-side. Be sure all four feet rest firmly on the counter.
PLUMBER’S INSTALLATION INSTRUCTIONS
IMPORTANT:
This equipment must be installed in accordance with the Basic
Plumbing Code of the Building Officials and Code Administrators
International (BOCA), and the Food Service Sanitation Manual of
the Food and Drug Administration (FDA). Also, this equipment
installation must comply with all local plumbing codes and
ordinances.
IMPORTANT:
Brewer must be installed on a water line with a full-flow pressure
between 20 psi and 90 psi.
NOTE: If water pressure varies greatly, or exceeds 90 psi at any
time, a water pressure regulator must be installed. Plumbing
installer must supply the regulator.
Brewer must be connected to a potable water supply. Bloomfield
recommends not less than 1/4” copper tubing for installations of
12’ or less, and not less than 3/8” copper tubing for installations
exceeding 12’. Brewer must be connected to a COLD water line.
NOTE: DO NOT use a saddle tap for this water line connection.
A shut-off valve must be installed between the main water supply
and the brewer. Plumbing installer must supply the shut-off valve.
A 1/4-turn ball valve is recommended.
Brewer INLET FITTING is 1/4" Male Flare.
Fig. 3 Water Line Installation
Flush the water line before connecting to the brewer.
CAUTION:
Hazard from
Unstable Equipment
Rubber feet must be installed
on each leg of the brewer.
Legs must be adjusted so that
all four feet rest firmly on the
counter. Failure to properly
install the feet can result in
movement of the brewer, which
can cause personal injury and/
or damage to the brewer.
Fig. 2 Adjustable Legs
IMPORTANT:
In some areas, local codes
require a backflow preventer
(check valve) to be installed on
the inlet water line. If a back-
flow preventer is used, you
must install a water hammer
arrester in the incoming line,
between the backflow preventer
and the brewer inlet, as far
away from the brewer as space
will allow. This will relieve the
excessive back pressures that
can cause faucet leaks and
solenoid malfunctions.
NOTE:
While new-style brewers
incorporate an internal strainer
in the inlet solenoid, the
provided "Y" strainer should be
installed in the incoming water
line for ease of servicing.
663 76061 Owners Manual for 9102A Single Satellite Brewer