Bosch Appliances HBN 74.. Double Oven User Manual


 
11
ELECTRICAL CONNECTIONS
4-WIRE BRANCH CIRCUIT
Refer to Figure B:
• Connect the green GROUND wire from the oven
to the GROUND wire in the junction box (bare
or green colored wire).
This appliance is manufactured with a green GROUND wire connected to the oven chassis. After making
sure that the power has been turned off, connect the flexible conduit from the oven to the junction box using
a U.L. listed conduit connector. Figures A and B and the instructions provided below present the most
common way of connecting the ovens. Your local codes and ordinances, of course, take precedence to these
instructions. Complete electrical connections according to local codes and ordinances.
3-WIRE BRANCH CIRCUIT
Refer to Figure A, where local codes allow the
connection of GROUND wire from the oven to the
branch circuit NEUTRAL wire (grey or white col-
ored wire):
If local codes permit, connect the green
Figure A
Junction box
Red wires
White
wires
Bare or
green wire
Cable
from oven
U.L.-listed conduit connector
Black wires
Grounded neutral
Junction box
Red wires
White wires
Bare or
green wire
Cable from
oven
U.L.-listed conduit connector
Black wires
Ungrounded neutral
Figure B
Cable from
power supply
Cable from
power supply
• Connect the red and black leads from the oven to
the corresponding leads in the junction box.
• Connect the white wire from the oven to the NEU-
TRAL (grey or white) wire in the junction box.
GROUND wire from the oven and the white wire
from the oven to the branch circuit NEUTRAL
wire (grey or white colored wire).
Connect the red and black leads from the oven to
the corresponding leads in the junction box.