Bosch Appliances HGS232UC Range User Manual


 
Thiskit isusedto convertonlydualfuelranges(model# HDS252U,HDS255UandHDS256U)andgasranges(model#
HGS232UC,HGS236UC,HGS242UC,HGS245UC,HGS246UC,HGS247UC,HGS252UC,HGS255UC,HGS256UC),fromnaturalgas
operationto propanegasoperation.ThiskitcannotbeusedtoconvertotherBoschmodelrangesorotherbrandranges.The
modelnumberonyourrangeisstampedontheplatebehindthewarmingorstoragedrawer.
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. Savethe natural gas parts for possibleconversion from LP
back to natural gas in the future.
PLFJ_E READ INSTALLA_ON INSII_UCT%ON$ BEFORE BE431NNINGTHE CONV£RSION.
This conversion kit shall be installed by a quali o
fled service agency in accordance with the
manufacturer's instructions and all applicable
codes and requirements of the authority having
jurisdiction, If the information in these instruc o
tions is not followed exactly, a fire, explosion
or production of carbon monoxide may result
causing property damage, personal injury or
loss of life, The qualified service agency is reo
sponsible for the proper installation of this kit,
The installation is not proper and complete uno
til the operation of the converted appliance is
checked as specified in the manufacturer's ino
structions supplied with the kit,
_J
High Altitude Installation:
For conversion in areas above 2,000 feet, contact Bosch
service for instructions: 800=944=2904.
f
_ CAUT][ON:
(!) When connecting theunit to the propane gas, make
certain the propane gas tank is equipped with its own
high pressure regulator. In addition, a pressure regulator
was supplied with the range. This second regulator must
be installed with the range. The maximum gas pressure
to this appliance is not to exceed :[4.0 inches water col=
umn from the propane gas tank regulator,
The following must be met when testing supply piping
system:
a) The appliance and its individual shut-off valve must
be disconnected from the gas supply piping system
at test pressures in excess of :[/2 psig (3.5 kPa).
b) The appliance must be isolated from the gas supply
piping system by closing its individual manual shut-
off valve during any pressure testing of the gas sup-
ply piping system at test pressures equal to or less
than :[/2 psig (3.5 kPa).
F For Massachusetts Installations: "
:[.Installation must be performed by a qualified or
licensed contractor, plumber or gas fitter qualified
or licensed by the state, province or region where
this appliance is being installed.
2.Shut=off valve must be a "T" handle gas cock.
3.Flexible gas connector must not be longer than 36
inches.
Kit Contents,
Conversion Kit Instructions
Conversion Sticker
4 LPOrifices (:[=70/:[=86/:[=:[0:[/:[=:[:[6)
Tools Required:
7 mm Socket Driver wi 3" extension
Torx (T20)=head screwdriver
Adjustable Wrench
Flat:head Screwdriver (:[/8" or smaller)
Phillips Head Screwdriver
Always Provide Adequate Gas Supply
The Bosch Freestanding Dual Fuel and GasRanges are shipped
from the factory for use with natural gas. Use this kit to con=
vert the appliance for LPgas use if necessary.
, Be sure the range is converted for use with the appropri=
ate gas before using it.
, Your range is designed to operate at a pressure of :[0" of
water column when used with LPgas.
, When checking for proper operation of the regulator, the
inlet pressure must be at least :[" greater than the operat=
ing (manifold) pressure above. When converting for LP
gas use, the pressure supplied to the regulator must be
between :[:[" and :[4" of water column. See step 2
"Convert Pressure to Regulator from 5" to :[0" W,C.",next
page.
, The pressure regulator located in the inlet of the range
manifold must remain in the supply line.
o Usea flexible metal appliance connector to connect the
range to the gas supply. The connector should have an
[.D. of :[/2" and be 5' in length. In Canada, the connector
must be single wall metal and no longer than 6: