5
SWITCH
COVER
SCREWS
SWITCH
MEMBRANE
SWITCH
BRACKET
INSTALL COOKTOP
1. Align the cooktop with the downdraft and fasten cooktop in
place.
Note: Accurate alignment of cooktop and downdraft is necessary
to ensure that there is no interference when air vent is raised and
lowered. There should be a gap of 1/32"-1/16" between the back
of the cooktop and the front of the downdraft cover.
ADJUSTMENT
The downdraft is factory-adjusted for proper operation. However,
shipping and handling may affect the position of the activating
switch.
To adjust position of activating switch:
WARNING: To avoid possible electrical
shock, personal injury or death -
Disconnect electrical power.
1. If downdraft is plugged into electrical outlet, unplug it.
2. Lift air vent straight up and cock it slightly so it remains in the
UP position.
KNOB
3. Remove switch cover from right end of air vent.
4. Loosen the 2 screws holding the switch bracket in place.
Position switch bracket so that activating switch just comes in
contact with underside of switch membrane. Tighten screws.
5. Replace switch cover, gently lower air vent into chimney, and
plug in power cord. Re-connect electrical power and check
operation.
USE AND CARE
Always turn the downdraft blower on before you begin cooking to
establish an air flow in the kitchen. Let the blower run for a few
minutes to clean the air after you turn the cooktop off. This will
keep the whole kitchen cleaner and brighter.
Turn the downdraft blower ON by pressing down on the activating
switch. The air vent will rise.
The blower can be turned ON or OFF and its speed can be
adjusted with the recessed knob on the right side of the air vent.
Turn the downdraft blower OFF by pressing the activating switch
again. The air vent will go down and the blower will shut OFF.
Note: For most convenient operation, set the blower to your
favorite speed. The blower will come on to this speed whenever
the activating switch is pressed and the air vent rises.
CLEANING
WARNING: Always disconnect electric
power supply before cleaning unit.
Use a mild detergent suitable for painted surfaces. DO NOT USE
ABRASIVE CLOTH, STEEL WOOL PADS, OR SCOURING
POWDERS. Vacuum blower to clean. Do not immerse blower in
water.
Wash the 2 aluminum grease filters in a mild detergent solution or
a dishwasher. Remove them from the air vent by grasping the tab
at the top of each filter.
Note: The filters are different sizes. Be sure to replace them as
removed, (wider one on the left), with tabs UP.
SERVICING
WARNING: Always disconnect electric
power supply before servicing unit.
It may be necessary to remove the outlet assembly from the
cabinet in order to service components such as the blower motor
or air vent mechanism.
Disconnect power to the cooktop and remove it first. Reverse the
steps under “MOUNT THE UNIT” to remove the downdraft from
the cabinet.
Service parts are available from your local distributor.
CONTROLS